Danger
Only allow properly qualified staff to carry out work on the electrical
equipment. Prior to establishing electrical connections check the maximum
permissible operating voltage.
►
Hint!
The electrical cable must be long enough to allow the control top to be
removed via the switch bar.
The cables must be suitable for use in the temperature range from -20
°C to 75 °C!
6.4.2
Electrical 24 V DC Wiring
6.4.2.1 Connector M12 / 5-pin, A-coded (24)
Fig.13:
5-pin M12 plug-in connector A-coded: device connector and view of pin strip
Corresponding cable socket see “Accessories” Section 5.4, Page 23.
1
L+
U
V
L+24 V DC supply voltage
2
Nominal value input
+
3
L-
U
V
L- reference potential
4
Setpoint output
+
5
Programming input
* Assignment for colour variant green, see "Colour changeover" Section 6.5.2,
Page 30.
Carry out the following steps:
1.
Connect cable via air connector M12/5-pin, A-coded.
®
Done.
Assembly and installation
Electrical connections
430BAL010747EN_3
28
24.07.2020