Fig.23
2.
Screw the switch bar (4) Mat. 221-589.87, into the piston rod (A4.1) and
tighten with open-end wrench SW 13, torque 3 Nm.
3.
Fit the control top (B) over the switch bar (4) and on the actuator.
4.
Tighten the clamp connection (15) and screws (39) to a torque of 1 Nm.
5.
Align the pneumatic and electrical connections in accordance with the valve
block configuration.
!
As internal air guiding is not possible for ASEPTOMAG valves, connect the
air connection (Y1) on the control top to connection (A.4.2) on the actuator
with an air hose (L).
6.
Carry out commissioning, see Section 7.2, Page 38.
®
Done.
6.6.8
Replacing Control Tops
When replacing the control top observe the following warning note:
Caution!
Collision of the switch bar with the pneumatic block
If a valve with the wrong type of switch bar is used, there is a risk of injury
as the switch bar can damage the pneumatic block.
► When replacing a predecessor model with a control top T.VIS P-15 the
switch bar must always be replaced!
Assembly and installation
430BAL010747EN_3
24.07.2020
37
Summary of Contents for T.VIS P-15
Page 65: ...Appendix 430BAL010747EN_3 24 07 2020 65 ...
Page 66: ......