Disconnect all power and utility lines.
•
Markings, e.g. on lines, must not be removed.
•
Do not climb on the component. Use suitable access aids and working
platforms.
•
Mark the lines (if unmarked) prior to disassembly to ensure they are not
confused when re-assembling.
•
Protect open line ends with blind plugs against ingress of dirt.
•
Pack sensitive parts separately.
•
For longer periods of standstill, observe the storage conditions, see
Section 4.1, Page 18.
10.2
Inspections
Checking parts are firmly secured
Fig.28
1.
Air hose connections
2.
Screw connection (B!) between hood (B) and base (5)
3.
Clamp (15)
4.
Plug
Further checking
1.
Check that the electrical connectors are properly secured.
2.
Check the sound absorber and the exhaust air throttle for soiling.
3.
Check the housing for mechanical damage.
®
Done
Maintenance
Inspections
430BAL010747EN_3
46
24.07.2020
Summary of Contents for T.VIS P-15
Page 65: ...Appendix 430BAL010747EN_3 24 07 2020 65 ...
Page 66: ......