®
Done
Hint!
The electrical cable must be long enough to allow the control top to be
removed via the switch bar.
10.2.4 Signs on the valve
Carry out the following steps:
1.
Check the signs on the valve.
2.
Replace damaged or missing stickers with new ones.
®
Done
10.3
Maintenance intervals
To ensure the highest operational reliability, all wearing parts should be replaced
at longer intervals.
The actual maintenance intervals can only be determined by the user since they
depend on the operating conditions, for instance:
•
daily period of use,
•
switching frequency,
•
type and temperature of the product,
•
type and temperature of the cleaning solution,
•
ambient conditions.
Maintenance Intervals
Applications
Maintenance intervals
(guideline values)
Media at temperatures of
60 °C to 130 °C
(140 °F to 266 °F)
approx. every 3 months
Media at temperatures of
< 60 °C
(< 140 °F)
approx. every 12 months
10.4
Prior to disassembly
Prerequisite:
•
Make sure that during maintenance and repair work no process is in operation
in the area concerned.
Carry out the following steps:
1.
Drain all pipe system elements that lead to the valve and, if necessary, clean
or rinse them.
Maintenance
Maintenance intervals
430BAL008360EN_5
40
07.02.2022
Summary of Contents for VARIVENT D Series
Page 20: ...Fig 7 Description 430BAL008360EN_5 20 07 02 2022...
Page 77: ...Appendix 430BAL008360EN_5 07 02 2022 77...
Page 78: ......