background image

 

 

 

Ventilation system 

GEALAN-CAIRE smart 

 

 

Operating manual 

English translation of the German original operating manual 

Last updated: 02/2021 

 

  

Summary of Contents for CAIRE smart

Page 1: ...Ventilation system GEALAN CAIRE smart Operating manual English translation of the German original operating manual Last updated 02 2021 ...

Page 2: ...roperty damage 8 Description 9 Control elements 9 Operating modes and LED indicators 10 Task and function 11 Power saving mode 11 Frost protection monitoring 12 Filters 12 Cover for closing the air ducts 12 Menu items 13 Technical data 14 Name plate 14 Operating the ventilation system 15 Operating the ventilation system with the buttons 15 Switching the ventilation system on and off 15 Switching o...

Page 3: ...Changing the filters 20 Maintaining the ventilation system 23 Troubleshooting 24 Disposal 26 Disposing of the filters 26 Disposing of the ventilation system 26 ...

Page 4: ... available This manual forms part of the ventilation system Ensure that this manual is available to the user at all times Supply this manual with the ventilation system if you ever sell it or pass it on in any other way Design features in the text Various elements of this manual are provided with specified design features This allows you to easily distinguish between the following elements Normal ...

Page 5: ... in the text they are given a number 1 Numbering starts with the number 1 for each figure Important details are magnified with magnifying glass views Manufacturer s address GEALAN Fenster Systeme GmbH Hofer Strasse 80 95145 Oberkotzau Germany Tel 49 0 92 86 77 0 Fax 49 0 92 86 77 22 22 Email info gealan de Web www gealan de ...

Page 6: ...ormation that is subject to copyright This manual may not be copied printed filmed processed reproduced or distributed in any form either in whole or in part without the prior written permission of GEALAN Fenster Systeme GmbH 2020 GEALAN Fenster Systeme GmbH All rights reserved ...

Page 7: ...fications to the ventilation system can result in serious or even fatal injuries Do not make any modifications to the ventilation system s components Basic safety instructions Incorrect handling of the ventilation system can result in serious injury and death Do not place any objects on the ventilation system Only use the ventilation system if it is in a technically perfect condition Contact your ...

Page 8: ...obstacles Furniture Bluetooth devices e g wireless keyboards wireless headphones etc Plants Electrical appliances e g microwave wireless cameras etc Water carrying elements Design features of warning notices WARNING Notes with the word WARNING warn of a dangerous situation that may potentially lead to death or serious injury Design features of notes on property damage ATTENTION These notices warn ...

Page 9: ... No Name 1 Button for operating the ventilation system 2 Fan cover for closing the air ducts under the cover strip When opened Fan unit switched on When closed Fan unit switched off External button for operating the ventilation system not shown ...

Page 10: ...Green Green Green Level 5 Green Green Green Green Green Automatic mode Green Frost protection or moisture protection Blue Blue Blue Blue Blue Blue Night cooling Turquoise Turquoise Turquoise Turquoise Turquoise Turquoise Cover closed Red Red Red Red Filter change necessary Flashes orange alternately with the operating mode e g alternately three green LEDs and six orange LEDs at level 3 Filter chan...

Page 11: ...rolled according to the humidity In manual mode the speed of the fans is controlled according to the set power level The ventilation system has one button and six RGB LEDs It can also be equipped and controlled with an external button as an option In addition the ventilation system can also be controlled over a WLAN WLAN control is carried out using the GEALAN Home app The LEDs indicate the curren...

Page 12: ...ers for supply air and exhaust air The filters have a limited service life and have to be changed regularly The filters service life depends on the volume of air that passes through them and is therefore dependent on the ventilation unit s operating mode The filters have their own data memory The operating hours and the running time are stored in this data memory depending on the operating mode Wh...

Page 13: ...Enable WLAN You can enable the WLAN in this menu item Disable WLAN You can disable the WLAN in this menu item Reset WLAN You can reset all of the WLAN settings with the exception of the device name in this menu item To this end the WLAN is disabled all the saved settings are deleted and the WLAN is reconfigured The communication processor is restarted after a few seconds The ventilation unit logs ...

Page 14: ...utput 60 W Input voltage 100 230 V AC Output voltage 24 V DC Protection class IP67 Name plate The name plate is located on the front of the ventilation system You will find the following information on the name plate Manufacturer s name and contact details Country of manufacture Model name Year of manufacture QR code CE mark WEEE Directive mark rubbish bin Input voltage range Serial number Item nu...

Page 15: ...both buttons when a button is mentioned below Switching the ventilation system on and off Slide the cover for closing the air ducts 1 to the open position The fans switch on Following switch on for the first time initial commissioning process or after a power failure the fan switches to automatic mode When switched on again the fan unit starts in the operating mode that was active last Slide the c...

Page 16: ...el 3 Power level 4 Power level 5 The LEDs in the case of horizontal installation starting from the left in the case of vertical installation starting from the bottom indicate the current fan state Standby mode is active one LED lights up yellow Power level 1 is active one LED lights up green Power level 2 is active two LEDs light up green Power level 3 is active three LEDs light up green Power lev...

Page 17: ...icate the relevant menu item The unit switches to the next menu item every six seconds The settings menu is closed once the last menu item is displayed Press the button once to select the relevant menu item The menu item currently displayed is selected and the settings menu is exited Refer to the table below for the colours of the LEDs for the relevant menu item No Menu item LED 1 LED 2 LED 3 LED ...

Page 18: ...Establishing a WLAN connection ATTENTION Obstacles e g furniture plants Bluetooth devices etc can cause malfunctions Ensure that there are no obstacles e g furniture plants Bluetooth devices etc between the ventilation system and the mobile terminal device Enable the WLAN according to the section entitled Selecting menu items see page 17 regarding this matter After switching on the WLAN for the fi...

Page 19: ...ial number may vary The serial number SN is attached to the ventilation unit If the sticker was removed by mistake you can ask your specialist dealer for the serial number with the WLAN SSID For security reasons you must change the password after logging in for the first time If you forget the password you must reset all of the WLAN settings in the settings menu see page 17 regarding this matter A...

Page 20: ...ventilation unit can no longer operate Filter change necessary and Filter change mandatory are indicated by orange LEDs see page 10 regarding this matter The LED closest to the filter to be changed is displayed slightly darker than the other LEDs This informs you which filter needs to be changed Proceed as follows to change the filters Switch off the ventilation system Remove the cover strip 1 ...

Page 21: ...Changing the filters 21 Open the two filter flaps 1 in the direction of the arrow Remove the used filters 2 ...

Page 22: ... Close the filter flaps 1 Attach the cover strip to the ventilation profile Switch on the ventilation system The LED indicator goes out The ventilation unit automatically detects the new filters and continues working in the most recently active operating mode ...

Page 23: ... possible due to electric shock or fire Always disconnect the ventilation system from the mains before performing maintenance work To do this switch off the fuse Ensure that no liquid gets inside the ventilation system If necessary clean the cover strip and the buttons with a clean damp cloth only ...

Page 24: ...NT_ ERROR_ TEMP_1 Temperature sensor 1 Exhaust air outside Off Red Off Off Off Off 2 _EVENT_ ERROR_ TEMP_2 Temperature sensor 2 Supply air inside Red Red Off Off Off Off 3 _EVENT_ ERROR_ TEMP_3 Temperature sensor 3 Supply air outside Off Off Red Off Off Off 4 _EVENT_ ERROR_ TEMP_4 Temperature sensor 4 Exhaust air inside Red Off Red Off Off Off 5 _EVENT_ ERROR_ HUMIDITY1 Humidity sensor 1 Supply ai...

Page 25: ...ed Off Off Red Red Off 25 _EVENT_ ERROR_ I2C_24XX I2C memory Off Red Red Red Red Off 30 _EVENT_ ERROR_ ESP32 Communication processor Off Off Off Off Off Red 32 _EVENT_ ERROR_ COMMUNI CATION Main processor Red Off Off Off Off Red 33 _EVENT_ ERROR_ POSITION Installation position of the ventilation unit ...

Page 26: ...lation system must be disposed of in an environmentally friendly manner Have the ventilation system dismantled by specialist personnel Dispose of the ventilation system through an approved specialist company or send it to your specialist dealer for disposal The ventilation system is mainly made of PA66 103HSL all injection moulded parts It also consists of the following materials Stainless steel s...

Reviews: