Description
11
Task and function
The ventilation system is used to aerate and ventilate frost-free rooms. It can
be used in private areas (living rooms, bedrooms, kitchens, showers,
bathrooms, storage rooms) or semi-public areas (offices, hotel rooms, daycare
centres, nursing homes).
Used, warm room air is extracted as exhaust air and discharged to the outside
as outgoing air. At the same time, fresh outside air is drawn in and introduced
into the rooms as filtered supply air.
The ventilation system has a position sensor. The position sensor detects
when the ventilation system is not in the correct position in the ventilation
profile. In this case, it blocks operation of the ventilation system.
The ventilation system has the following operating modes:
•
a manual mode
•
a standby mode
•
an automatic mode.
In automatic mode, the speed of the fans is controlled according to the
humidity. In manual mode, the speed of the fans is controlled according to the
set power level.
The ventilation system has one button and six RGB LEDs. It can also be
equipped and controlled with an external button as an option.
In addition, the ventilation system can also be controlled over a WLAN. WLAN
control is carried out using the GEALAN Home app.
The LEDs indicate the current state of the ventilation system, filter change and
errors. When the ventilation system is in operation, the LEDs switch on
automatically. They switch off after two minutes by default. LED switch-off can
be set in the GEALAN Home app.
Power-saving mode
When the ventilation unit is in standby mode and the set time to LED switch-
off has elapsed, the ventilation unit starts power-saving mode. Power-saving
mode is not displayed separately. Access to the ventilation system through the
GEALAN Home app is still possible. The power-saving mode is automatically
ended as soon as the ventilation system is operated or the LED switch-off is
disabled.