Consumer Support
Installation Instructions
Tr
oubleshooting T
ips
Operating Instructions
Safety Instructions
47
4-Wire Conduit Installation Option
Remove the bracket with a 1
3
⁄
8
″
diameter
opening from the rear of the range and
retain the screws.
Locate the bracket with a 1
1
⁄
8
″
diameter
opening in the installation accessory pack
(packed with the oven shelves on new
ranges).
Install the new bracket to the rear of the
range, below the terminal block, using the
screws removed above.
Insert the conduit through the strain relief
and tighten. Allow enough slack to easily
attach the cord terminals to the connector
block. If tabs are present at the end of the
winged strain relief, they can be removed
for better fit.
NOTE:
Do not install the conduit without a strain
relief. The strain relief bracket should be installed
before reinstalling the rear range wiring cover.
Insert bare wires between the connector
block terminals and movable nuts. Tighten
screws securely. Attach ground wire to the
grounding plate using the ground screw.
WARNING:
Connector block is approved
for copper wire connection only. If aluminum wire is
used, see note below.
NOTE:
ALUMINUM WIRING
Do not connect aluminum wire to
the connector block.
Use copper building wire rated for
the correct amperage and voltage to
make three 3
″
copper jumper wires.
Splice copper wires to aluminum
wiring using special connector
terminals designed and UL-approved
for joining copper to aluminum and
follow the connector manufacturer’s
recommended procedure closely.
Wire used, location and enclosure of splices,
etc., must conform to good wiring practices
and local codes.
Screw
Flexible cable
Bare wire
tips
Conduit
Bare wire
Movable nut
Connector block
Bracket
Connector block
terminal
Grounding
plate
Bracket
1
1
⁄
8
″
dia. opening