background image

8

(Continued on following page)

Installation Instructions

Electrical Connections

ATTENTION INSTALLER

All electric wall ovens must be hard wired
(direct wired) into an approved junction
box. A plug and receptacle is NOT permitted
on these products.

DO NOT shorten the flexible conduit.
The conduit strain relief clamp must be
securely attached to the junction box
and the flexible conduit must be securely
attached to the clamp. If the flexible
conduit will not fit within the clamp, do not
install the oven until a clamp of the proper
size is obtained.

NOTE TO ELECTRICIAN: The 3 power
leads supplied with this appliance are
UL recognized for connection to heavier
gauge household wiring. The insulation
of these 3 leads is rated at temperatures
much higher than the temperature rating
of household wiring. The current carrying
capacity of the conductor is governed
by the wire gauge and the temperature
rating of the insulation around the wire.

Turn off the circuit breaker or remove
fuses to the oven branch circuit.

With the oven supported on a table or
platform in front of the cabinet opening,
connect the flexible conduit to the
electrical junction box as shown below.
Position the conduit in such a manner
that it will lie on top of the oven in
a natural loop when the oven is
installed. You will need to purchase
an appropriate strain relief clamp to
complete the connection of the conduit
to the junction box.

WARNING:

 Improper

connection of aluminum house
wiring to copper leads can

result in an electrical hazard or fire.
Use only connectors designed for
joining copper to aluminum and follow
the manufacturer’s recommended
procedure closely.

B2

B1

B

Junction Box
Location

5

Strain Relief Clamp
(not included)
must be used at
Junction Box

BARE

GROUND

WHITE

Place oven on a
support to assist in
connecting conduit

RED

BLACK

Conduit
48 1/2

long

GROUND

WIRE

Summary of Contents for JTP25SH

Page 1: ...onduit 48 1 2 long 5 27 1 4 MIN 27 5 16 MAX Cutout height A B 23 1 2 MIN Cutout depth 22 MIN Note Cabinets installed adjacent to wall ovens must have an adhesion spec of at least a 194 F temperature rating Installation Information Before installing consult installation instructions packed with product for current dimensional data C L Must Support 275 LBS 2 x 4 or equivalent runners Suitable bracin...

Page 2: ...e location For a 30 gas cooktop the connections are more conveniently made to the right 120 Volt Outlet Gas connection Junction box location 240 208V 36 MIN 4 To 4 1 2 Toe kick allowable Match toe kick height front and two sides 22 MIN above support platform Top and or side fillers may be necessary if unit is positioned between existing cabinets 28 1 2 MIN 28 5 8 MAX 27 1 4 MIN 27 5 16 MAX Cutout ...

Page 3: ...tronic oven controls One touch electronic pads are easy to use and allow for simple oven operation TrueTemp system Delivers even heat distribution and maximum oven control Big ClearView window An extra large clear window makes monitoring the progress of the food easy Interior oven light Supplies light to make viewing the progress of cooking easy and convenient Dual element bake Alternates the uppe...

Page 4: ...s for future reference Proper installation is the responsibility of the installer and product failure due to improper installation is NOT covered under warranty NOTE This appliance must be properly grounded ATTENTION INSTALLER All electric wall ovens must be hard wired direct wired into an approved junction box A plug and receptacle is NOT permitted on these products Tools Needed 1 8 Drill Bit and...

Page 5: ...cal utilities for electrical codes which apply in your area Failure to wire your oven according to governing codes could result in a hazardous condition If there are no local codes your oven must be wired and fused to meet the requirements of the National Electrical Code ANSI NFPA No 70 Latest Edition You can get a copy by writing National Fire Protection Association Batterymarch Park Quincy MA 02...

Page 6: ... TRICA L REQU IREME NTS Befor e you begin Read these instru ctions comp letely and carefu lly IMPO RTAN T Save these instru ctions for local inspe ctor s use IMPO RTAN T OBSE RVE ALL GOVE RNING CODE S AND ORDIA NCES Note to Instal ler Be sure to leave these instru ctions with the consu mer OWNE R Keep these instru ctions for future refere nce Note This applia nce must be prope rly groun ded if app...

Page 7: ...orm must support 150 lbs single 275 lbs double Installation Instructions Pre Installation Checklistcont Remove the bottom trim from the top of the oven It will be installed at the end of the installation process The trim is wrapped separately and taped to the top of the unit ...

Page 8: ...out opening are visible above the installed oven it may be necessary to add wood shims under the runners and front trim until the marks or opening are covered CUTOUT HEIGHT 27 1 4 MIN 27 5 16 MAX CUTOUT WIDTH 28 1 2 MIN 28 5 8 MAX 5 22 TO BOTTOM OF JUNCTION BOX JUNCTION BOX LOCATION RECOMMENDED CUTOUT LOCATION 32 1 2 FROM THE FLOOR CABINET WIDTH 30 ALLOW 11 16 FOR OVERLAP OF THE OVEN OVER SIDE EDG...

Page 9: ...installed oven it may be necessary to add wood shims under the runners and front trim until the marks or opening are covered CUTOUT HEIGHT 51 13 16 MIN 51 15 16 MAX 5 CUTOUT WIDTH 28 1 2 MIN 28 5 8 MAX 47 TO BOTTOM OF JUNCTION BOX JUNCTION BOX LOCATION ALLOW 11 16 FOR OVERLAP OF THE OVEN OVER SIDE EDGES OF CUTOUT THE OPENING BETWEEN INSIDE WALLS MUST BE AT LEAST 28 1 2 WIDE ALLOW 1 FOR OVERLAP ON ...

Page 10: ...n in the cabinet 3 4 Support Platform Required MUST SUPPORT 150 LBS 22 MIN Above Support Platform 5 9 16 Reference dimension for maximum support height with typical 36 countertop height MUST SUPPORT 150 LBS 3 4 Support Platform Required 25 5 24 Gas and electrical connections for 30 gas cooktop must be located in an adjacent accessible location to the right For 36 gas cooktop the connections may be...

Page 11: ...ity of the conductor is governed by the wire gauge and the temperature rating of the insulation around the wire Turn off the circuit breaker or remove fuses to the oven branch circuit With the oven supported on a table or platform in front of the cabinet opening connect the flexible conduit to the electrical junction box as shown below Position the conduit in such a manner that it will lie on top ...

Page 12: ...alling in new construction or When installing in a mobile home or When installing in a recreational vehicle or When local codes do not permit grounding through neutral a Cut the neutral white lead from the crimp Re strip the neutral white lead to expose the proper length of conductor b Attach the appliance grounding lead green or bare copper in accordance with local codes If the residence groundin...

Page 13: ...tring around the conduit before the oven is slid into place This will keep the conduit from falling behind the oven b Lift oven into cabinet cutout using the oven opening as a grip Carefully push against oven front frame Do not push against outside edges c As you slide the oven back pull the string so that the conduit will lie on top of the oven in a natural loop d When you are sure the conduit is...

Page 14: ...ack of the trim d Push the trim down at both ends until it snaps securely into place c Match the key slot with the rivet on the bottom of the side trim and lower the trim onto the rivet C5 Lower Trim Mounting Rivet on End of Metal Lower Trim Key Hole Slot and Wide Flange at Top Preparing for the Bottom Trim Installation C3 Side Trim Trim Screws Side Trim Metal Lower Trim CAUTION Be sure you do not...

Page 15: ... must be fully seated into the bottom of the slot Open the oven door as far as it will open Push the hinge locks up against the front frame of the oven cavity to the locked position Close the oven door Installation Instructions Replacing the Oven Door D NOTE The oven door is heavy You may need help lifting the door high enough to slide it into the hinge slots Do not lift the door by the handle D1 ...

Page 16: ... s Manual for troubleshooting list Operation Checklist NOTE TO ELECTRICIAN The power leads supplied with this appliance are UL recognized for connections to larger gauge household wiring The insulation of these leads is rated at temperatures much higher than the temperature rating of household wiring The current carrying capacity of a conductor is governed by the wire gauge and also the temperatur...

Page 17: ...14 NOTES ...