ATTENTION!!!

After you have made yourself familiar with the functions of the 
appliance, please program your personal mastercode as well as a 
pass code with which you replace the pass code which is located 
on the memory place 00. Only by this your Cody Universal 2 is 
protected against manipulation!

TIPTOMATIC:

The Cody Universal 2 has two potential free relay outputs enabling 
direct control of a tubular drive or an industrial door drive unit or similar 
instruments. After having entered a valid pass code 

the user can, 

within a period of 60 seconds, trigger the installed drive unit in the 
dead man’s mode with the arrow keys UP 

    

and DOWN         . 

The relay is activated only as long as the 

arrow keys are pushed. The 

two relays are interlocked against each other, so it is not possible that 
both relays can be switched at the same time. After expiration of the of 
60 seconds the Cody  Universal 2 locks automatically.  This function, 
however, can be interrupted prior to the expiration of the 60 seconds, 
by pressing the         button.

Lock-out function:

If the lock-out function is activated, the Cody Universal 3 automatically 
blocks any input for a set period after the input of a wrong pass code 
which is signalled with a (3 beeps) sound signal.
You can freely program the lock-out time according to your 
requriments.
The end of the lock-out time is signalled by a long sound signal.

General reset

General reset

Push reset button 

on the PCB 

> 5 sec.

Factory setting (default setting):

 all memories erased (except 00)

 mastercode = sequence 1-8

 pass code 00 = sequence 1-4

 Tiptomatic-time = 60 sec.

 look-out time = 20 sec.

Put DIP switch 4 to 

ON 

Put DIP switch 

back to OFF

All factory settings are restored by the general reset !

Summary of Contents for Cody Universal 2

Page 1: ...5 V1 0 Cody Universal 2 GB Assembly connection and maintenance of the device may only be executed by personnel trained accordingly At this the underlying national and local regulations have to be obse...

Page 2: ...the company with the master code 12345678 Pass code The pass code is either a four or five digit numeral code by which you operate your door drive unit You have the possibility to store up to 50 diff...

Page 3: ...ach other so it is not possible that both relays can be switched at the same time After expiration of the of 60 seconds the Cody Universal 2 locks automatically This function however can be interrupte...

Page 4: ...therwise the water protection ot the appliance cannot be assured 6 According to connection diagram connect the wires to the corresponding terminals Transponder Program 2 Deleting transponder keys Dele...

Page 5: ...nted directly on metal Then use a spacer case No 508 000G 00 Program 1 Teach in of transponder keys Put the desired key to the reader LED flashes 1x long Technical Data Supply voltage 230 240 V AC Out...

Page 6: ...de to your personal code of choice Enter 8 digit mastercode The new mastercode is now saved Program 6 Entering a pass code Keypad Enter 4 or 5 digit pass code button push button push push button A cor...

Page 7: ...tton button push push button push push button push button push button Program 2 Creating a new pass code Factory setting 1 4 The new pass code is now saved You can enter up to 50 different pass on the...

Page 8: ...button push button Enter 3 digit time 001 255 Program 3 Deleting a pass code push button push button push button push button Enter of 2 digit memory slot e g 07 or 28 sound signal 2x long Enter 8 dig...

Reviews: