background image

Transponder

Keypad

Transpond
er

Cody

Netz

230/240VAC

M

230/240VAC

Transponder

* Note:
   Cody Universal 2
   The keys are distributed among three blocks with each 255 keys of on color. The blocks
   correspond to the first 3 DIP switches.

ATTENTION:
It is not possible to teach-in key different colors in one and the same block!
The reader should not be mounted directly on metal. Then use a spacer case (No. 508.000G.00).

Program 1
Teach-in of transponder keys

Put the desired 

key to the 

reader

LED flashes

(1x long)

Technical Data:

Supply voltage: 230-240 V AC
Output: 250V AC 5A 
Connections: 1.5 mm² max.
Ambient temperature: -20 °C to +60 °C 

This product complies with:
EC Electromagnetic Compatibility Directives
EN 61000-6-1 08/2002
EN 61000-6-3 08/2002
Low Voltage Directive 2006/42/EC

Put DIP of the 

desired relay or block 

* (1/2/3) to ON

Set all DIP to 

OFF

The transponder key is programmed to the desired block! 

Summary of Contents for Cody Universal 2

Page 1: ...5 V1 0 Cody Universal 2 GB Assembly connection and maintenance of the device may only be executed by personnel trained accordingly At this the underlying national and local regulations have to be obse...

Page 2: ...the company with the master code 12345678 Pass code The pass code is either a four or five digit numeral code by which you operate your door drive unit You have the possibility to store up to 50 diff...

Page 3: ...ach other so it is not possible that both relays can be switched at the same time After expiration of the of 60 seconds the Cody Universal 2 locks automatically This function however can be interrupte...

Page 4: ...therwise the water protection ot the appliance cannot be assured 6 According to connection diagram connect the wires to the corresponding terminals Transponder Program 2 Deleting transponder keys Dele...

Page 5: ...nted directly on metal Then use a spacer case No 508 000G 00 Program 1 Teach in of transponder keys Put the desired key to the reader LED flashes 1x long Technical Data Supply voltage 230 240 V AC Out...

Page 6: ...de to your personal code of choice Enter 8 digit mastercode The new mastercode is now saved Program 6 Entering a pass code Keypad Enter 4 or 5 digit pass code button push button push push button A cor...

Page 7: ...tton button push push button push push button push button push button Program 2 Creating a new pass code Factory setting 1 4 The new pass code is now saved You can enter up to 50 different pass on the...

Page 8: ...button push button Enter 3 digit time 001 255 Program 3 Deleting a pass code push button push button push button push button Enter of 2 digit memory slot e g 07 or 28 sound signal 2x long Enter 8 dig...

Reviews: