background image

geba GmbH 

is released of its obligations regarding guarantee and product liability if – without prior 

permission - the unit has been modified, or if the installation is unproper or not in accordance with our 
instruction manual. The installer has to take care that the EMC-regulations are respected.

Interior mounting of the logic:

1. Put the screw-driver into the gap of the enclosure front, push the screw-driver up and
    open the enclosure.
2. Remove the control PCB (which is force fitted to the inside of the enclosure).
3. Locate the screwed glands supplied (sealing nipple left side) in the
    enclosure and replace the PCB. (Please ensure PCB is firmly in position)
4. Bore the fastening holes and fix the enclosure bracket at the wall.
5. The wires for the keyboard ensure through the left cable entry (sealing nipple), the wires
    for the relay contact through the middle cable entry and the wires for the supply voltage ensure              
through the right cable entry. Ensure tight seating of sealing nipple and cable gland, otherwise the          
water-protection ot the appliance cannot be assured.
6. According to connection diagram connect the wires to the corresponding terminals:

Mounting instructions

The specific transmitter is now deleted!

RC transmitter

Program 2
Deleting of remote controls

Delete specific transmitter:

The taught-in transmitters are now all deleted !

Set DIP 1 to 

ON

Press the button of the 

RC transmitter 

> 5 sec. 

Put all DIP to OFF

Press the reset 

button on the 

logic board

> 5 sec. 

Put 

DIP 4 to ON 

LED flashes

2x long

Delete all transmitters :

Put all DIP to OFF

Put 

DIP 4 to ON 

Set DIP 1 to 

ON

Summary of Contents for Cody Universal 3

Page 1: ...6 V1 1 Cody Universal 3 GB Assembly connection and maintenance of the device may only be executed by personnel trained accordingly At this the underlying national and local regulations have to be obse...

Page 2: ...et by the company with the master code 12345678 Pass code The pass code is either a four or five digit numeral code by which you operate your door drive unit You have the possibility to store up to 50...

Page 3: ...o it is not possible that both relays can be switched at the same time After expiration of the of 60 seconds the Cody Universal 3 locks automatically This function however can be interrupted prior to...

Page 4: ...he enclosure bracket at the wall 5 The wires for the keyboard ensure through the left cable entry sealing nipple the wires for the relay contact through the middle cable entry and the wires for the su...

Page 5: ...tage 20 28V AC DC 230 240 V AC Output 250V AC 5A Connections 1 5 mm max Ambient temperature 20 C to 60 C Keypad Program 1 Teach in of remote controls RC transmitter Make sure before the teach in that...

Page 6: ...es please check the faultless function of the appliance with the help of the factory s pass code 1234 and the button Usually any programming is made via your personal mastercode In order to get famili...

Page 7: ...00G 00 The transponder key is programmed to the desired block push button push button Program 2 Creating a new pass code Factory setting 1 4 sound signal 2x long Enter 8 digit mastercode Enter 2 digit...

Page 8: ...t mastercode Enter 3 digit time 001 255 The modified lock out time is saved Lock out time dynamic The lock out time is extended by 10 sec with every wrong entry max 255 sec static The lock out time is...