2
The 2 x 6 framework must be secured firmly to the
floor and ceiling for proper installation. Locate the
supporting studs and reinforce with additional nails
or screws.
Make sure rough opening(s) are properly plumbed
and square.
3
1. Place the tank & carrier assembly into the desired location. The carrier metal frame must be flush with the front
of the mounting studs to provide maximum support for the wall surface (applied later).
2. Mark the 6 anchor hole locations in the base and the 4 side mounting hole locations (2 each side) on the studs.
3. If the discharge is to be installed vertically in ground, mark the discharge elbow location on the base support.
4. Remove the tank & carrier assembly from the studs.
5. Drill six 3/16" holes in the base support; drill four 5/16" holes on the side studs where marked.
6. For vertical discharge only, bore a 4" hole into the base plate where marked.
7. Install tank & carrier into framework and secure with hardware provided.
8. Install 3" shielded coupling (provided) to connect discharge elbow to waste pipe.
TANK & CARRIER INSTALLATION
Reinforce with additional
nails or screws
Side Mounting Hole Locations
5/16" (2 each side)
6 Base Anchor
Holes (3/16")
Vertical In Ground Installation
Horizontal Above Ground Installation
Finished Seat
Height
5¼"
(133 mm)
X
T + FSH - 5¼ = X
Distance between
top of the bowl rim surface
and discharge outlet centerline
Distance between
discharge outlet centerline
and raw floor
T
1
IMPORTANT! The Finished Seat Height for the bowl must be determined
prior to
installing the carrier. Please
take into account the seat height for final height dimensions.
NOTE: When determining X, include the dimension for the finished floor covering (up to .5").
ww