11
GD= grooved cable drum
Chart 1
Type WW250 >> 1500 kg
WW
2
5
0
..
/D
WW
2
5
0
..
/GD
WW
2
5
0
..
/2
D
WW
5
0
0
..
/D
WW
5
0
0
..
/GD
WW
5
0
0
..
/2
D
WW
1
0
0
0
.
./
D
WW
1
0
0
0
.
./
G
D
WW
1
0
0
0
.
./
2
D
WW
1
5
0
0
.
./
D
WW
1
5
0
0
.
./
G
D
WW
1
5
0
0
.
./
2
D
Hoisting load first layer
Kg
250
2x125
500
2x250
1000
2x500
1500
2x750
Hoisting load last layer
Kg
95
2x48
239
2x120
542
2x271
845
2x375
Cable diameter
mm
5
4
6
5
9
6
10
9
Min. breaking force of cable
kN
15,9
10,2
22,9
15,9
51
22,9
63
51
Max. Cable storage calculated per
cable compartment
m
59
49
77
48
55
72
42
26
Max. cable layers per cable
compartment
11
14
9
12
7
12
6
7
Crank force first layer
daN
6
6
10
10
13
13
14
14
Transmission ratio
1:10
1:10
1:12
1:12
1:26
1:26
1:37
1:37
Hoisting height per crank rev.
mm
17
17
20
20
13
13
9
9
Own weight
Kg
13
13,5
16
16,5
29
27,5
28
28,5
Wall fastening, class 8.8 bolts
4xM12
4xM12
4xM12
4xM12
4xM16
4xM16
4xM16
4xM16
Permitted environment
temperature
-10°C / +50°C
Dimensions