CAUTION
(MAY CAUSE PROPERTY DAMAGE)
•
DO NOT open or service the pump. There are no “user servicable” parts or
assemblies inside. This pump contains dielectric oil used to cool down the
motor. The amount of oil contained herein was precisely measured for
optimum performance. Opening or altering the pump will void the warranty.
•
This pump is a Type Y Attachment. If the power cord needs to be replaced,
please contact your local authorized dealer.
WARNING
−
RISK OF ELECTRIC SHOCK.
Connect only to a circuit
protected by ground-fault circuit-interrupter. The unit should be installed by a
qualified service representative. All electrical wiring of the motor installation must
be done by a qualified electrician in accordance with applicable electrical codes.
Grounding is required. Before working on any motor, be certain that the source
of electrical power is off at the main junction box
.
TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
SOLUTION
Power cord not plugged in
Plug in power cord
Power supply is OFF
Turn power supply ON
and/or replace fuse
Air switch is OFF
Depress the air button
Ground Fault Circuit
Interrupter (GFCI) tripped
Unplug power cord, reset
GFCI, check power in
receptacle and plug in
power cord
Pump Does Not Run
Motor over heats
Let the motor cool down
Air tube disconnected
Connect tube to air switch
and air button nipples,
secure
Air tube damage/leaks
Replace tube
Air tube kinked
Remove kink and properly
route the tube
Air button damaged
Replace air button
Pump Still Does Not Run,
Even After Performing #1
Air switch damaged
Replace air switch
Closed valves
Open valves
Low water level in jetted
bath
Fill jetted bath up to the
normal bath water level
Airlock in the plumbing
Bleed air from plumbing
Pump Runs But Low or No
Water Pressure on Jets
Clogged or blocked
plumbing
Open air-venturi control
valve to release air trapped
in plumbing
SAVE THESE INSTRUCTIONS
.
Summary of Contents for Aqua-Flo Therma-Flo Enviro-Heat Series