Standard config. #

Pump 1 

Pump 2 

Pump 3 

Blower

Circ. Pump (CP) 

configuration

Ozone (O3) 

configuration

1

Filter cycle

daily

Heater pump

1

2SP

(A3)

10A-4A

_

_

_

_

During filter cycle with P1

(A1)

2 * 2 hour

with P1

with P1

12A

2

2SP

(A3)

10A-4A

1SP

(A1)

6A

_

_

_

_

2 * 2 hour

with P1

with P1

12A

3

2SP

(A3)

10A-4A

_

_

X

(A1)

4A

_

_

2 * 2 hour

with P1

with P1

12A

4

2SP

(A3)

10A-4A

_

_

_

During filter cycle

(A1 )

3A

_

2 * 6 hour

with CP

with CP

12A

5

1SP

(A3)

10A 

_

_

_

During filter cycle

(A1 )

3A

During filter cycle with CP

(A2)

2 * 6 hour

with CP

with CP

12A

6

1SP

(A3)

10A 

1SP

(A2)

6A

_

_

During filter cycle

(A1 )

3A

_

2 * 6 hour

with CP

with CP

12A

7

1SP

(A3)

10A 

_

_

X

(A2)

4A

During filter cycle

(A1 )

3A

_

2 * 6 hour

with CP

with CP

12A

8

1SP

(A3)

10A 

1SP

(A2)

6A

1SP

(A1)

12A

_

Always on

(A0)²

1A

_

2 * purge

CP always on

with CP

12A

9

1SP

(A3)

10A 

1SP

(A2)

6A

_

X

(A1)

4A

Always on

(A0)²

1A

_

2 * purge

CP always on

with CP

12A

10

2SP

(A3)

10A-4A

1SP

(A1)

6A

_

_

Always on

(A0)²

1A

_

2 * purge

CP always on

with CP

12A

11

2SP

(A3)

10A-4A

_

_

X

(A1)

4A

Always on

(A0)²

1A

_

2 * purge

CP always on

with CP

12A

12

2SP

(A3)

10A-4A

1SP

(A1)

12A

_

_

_

2 * 2 hour

with P1

with P1

12A

13

1SP

(A3)

10A 

1SP

(A1)

12A

_

_

During filter cycle

(A2)

3A

_

2 * 6 hour

with CP

with CP

12A

14

1SP

(A3)

10A 

1SP

(A1)

12A

_

X

(A2)

4A

Always on

(A0)²

1A

_

2 * purge

CP always on

with CP

12A

15

2SP

(A3)

12A-4A

1SP

(A1)

12A

_

_

Always on

(A0)²

1A

_

2 * purge

CP always on

with CP

12A

16

2SP

(A3)

10A-4A

_

_

_

During filter cycle

(A1)

3A

_

2 * 2 hour

with P1

with CP

12A

Configuration selection chart

Software #382, rev. 003

For complete TechBook or more information, see our website: www.geckoalliance.com

9919-101496-C 

Rev. 11-2017

www.geckoalliance.com

© Groupe Gecko Alliance Inc., 2017
All trademarks or registered trademarks are the property of their respective owners.

1

  When the Ozonator is not controlled by a relay, it can be tied to Pump 1 Low speed or Circ. Pump. Pump using cable splitter AMP PN: 9920-401369.

A0 floating connector use Black: P28, White: Any available N connector, Green: Any available G connector. Floating connector not supplied. Part #9920-401346.

Glossary

(P1L) 

Pump 1 Low speed

(CP)  

Circulation Pump

X

 

 

Installed  

1SP

  

High speed only 

2SP

  

High and Low speed

(OUT, AMP, Relay, Tab) 

Output connector 

13A-4A

 

Current High - Low speed