background image

 

G320X SERVO DRIVE

 

REV 10: May 13, 2010 

 

 

Thank you for purchasing the G320X drive. The G320X DC servo drive is warranted to be free of manufacturing defects for 1 year 
from  the  date  of  purchase.    Any  customer  who  is  dissatisfied  with  it  or  is  unable  to  make  it  work  will  be  cheerfully  refunded  the 
purchase price if the G320X is returned within 15 days of the purchase date. 
 

PLEASE READ FIRST BEFORE USING THE G320X: 

 
If you are not familiar with DC servo drives please do the following setup instructions with the motor on the bench before mounting it 
on the mechanism it will eventually run. This will allow you to get a baseline motor behavior of what to expect. 
 
Before  you  start,  you  must  have  a  suitable  encoder  mounted  and  properly  aligned  on  the  motor.  Follow  the  manufacturer’s 
instructions on mounting and aligning the encoder if the motor doesn’t already come with one. 
 
Next you must have a DC power  supply suitable for the motor. The power supply current rating must equal the maximum current 
you expect to run the motor at. 
 
Finally, have a STEP and DIRECTION pulse source available. 
 
Before going on, turn the “P”, “I”, “D”, and LIMIT trimpots to the 11 o’clock position. The trimpots are single-turn so be careful not to 
over-torque them. 
 

G320X PINOUT 
 
TERMINAL 1 

Power Ground 

 

 

Connect the negative (black) lead of your power supply to this terminal. 

 

TERMINAL 2 

Power (+) 
Connect the positive (red) lead of your power supply to this terminal. It must be b18VDC to +80VDC. 

 

TERMINAL 3 

Armature (-) 

 

 

Connect the black lead of your motor to this terminal. 

 

TERMINAL 4 

Armature (+) 

 

 

Connect the red lead of your motor to this terminal. 

 

TERMINAL 5 

ERR/RES 
This is the ERROR and RESET pin. For a full explanation read the section titled “ERROR/RESET PIN” on page 
6. 

 

TERMINAL 6 

Encoder Ground 

 

 

Connect the encoder power supply ground to this terminal. 

 

TERMINAL 7 

E5VDC 

 

 

Connect the e5VDC pin to this terminal. 

 

TERMINAL 8 

Channel A 
Connect the Channel A pin of your encoder to this terminal. 
 

TERMINAL 9 

Channel B 

 

 

Connect the Channel B pin of your encoder to this terminal. 

 

TERMINAL 10 

Direction 

 

 

Connect the DIRECTION signal to this terminal. 

 

TERMINAL 11 

Step 

 

 

Connect the STEP signal to this terminal. 

 

TERMINAL 12 

S/D Common 

 

 

Connect this terminal to 5VDC or signal ground. 

 
 
 

Summary of Contents for G320X

Page 1: ...at Finally have a STEP and DIRECTION pulse source available Before going on turn the P I D and LIMIT trimpots to the 11 o clock position The trimpots are single turn so be careful not to over torque...

Page 2: ...256 count following error limit default SW4 OFF and SW5 ON 512 count following error limit SW4 ON and SW5 OFF 1024 count following error limit SW4 OFF and SW5 OFF 2048 count following error limit SW6...

Page 3: ...POWER SUPPLY IMPORTANT Never put a switch on the DC side of the power supply This will damage if not destroy your drive Keep the power supply leads short and use the largest wire gauge that will easil...

Page 4: ...this terminal STEP 7 TUNING THE SERVO Turn on the power supply The FAULT indicator should turn off and the IN POSITION indicator should turn on after 1 second If everything is correct you may hear fa...

Page 5: ...momentary load on the motor while the oscilloscope shows how it responds see oscilloscope traces above If you are using an oscilloscope use channel 1 on TP1 and channel 2 on the DIRECTION input Set t...

Page 6: ...r on reset circuitry in the G320X It will stay in this state indefinitely until it is cleared by applying 5V to this terminal for at least 1 second The voltage on this terminal is 5VDC when the G320X...

Page 7: ...Feedback Resolution X4 Encoder Line Count Feedback Voltages 1V for Logic 0 and 4V for Logic 1 Switching Frequency 20kHz Current Limit 0 to 20 Amps Trimpot Adjustable Analog PID Proportional Derivativ...