MANUAL BCSI-1 REV 1.8 EN.DOC
19.12.08
A.J.
- 11 -
BCSi
BCSi
BCSi
BCSi----RF 10 / BCSi
RF 10 / BCSi
RF 10 / BCSi
RF 10 / BCSi----RF100:
RF100:
RF100:
RF100:
Charging voltage:
X92
X92
X92
X92, Intrinsically safe ia:
Contact inside: +Ui
Contact outside: GND
Ui
≤
10,8 V
Ii
≤
not important
Pi
≤
not important
Li
≤
negligible
Ci
≤
negligible
Uo
≤
negligible
Io
≤
negligible
Po
≤
negligible
Lo
≤
negligible
Co
≤
negligible
Recommended max. cable length 5m (16,4ft).
Pay attention to the values listed in corresponding standards.
Terminal Connections
BCSi-C LP, BCSi-C HP:
Supply voltage / Data interface X91:
X91
Function
Cable
Connector
+Ui
Brown
1
6
GND
White
2
7
RXD (inp.)
Yellow
3
2
TXT (outp.)
Green
4
3
BCSi-RF 10, BCSi-RF 100:
Supply voltage interface X92:
X91
Function
Connector
+Ui
Contact inside
GND
Contact outside
Further details can be found in attached installation plan drawings of different variants.