background image

 

Electrical connection :

 The apparatus is designed to 

operate from a 230V 50Hz supply only. (Classified as 
«hazardous voltage» according to EN60950 standard). 
The apparatus does not incorporate an integral power   
on/off switch. To disconnect the power, either switch off 
supply at the mains power socket or unplug the AC 
adaptor. When installing the apparatus, ensure that the 
mains power socket is readily accessible. 

 
Telephone connection :

 Voltages present on the 

telecommunication network are classified TNV-3 
(Telecommunication Network Voltage) according to the 
EN60950 standard. 

 

 

 

 

 

 

 

 

 

 

 

INSTALLATION

 

Summary of Contents for AMPLICALL 10

Page 1: ......

Page 2: ...ol Tone control Speaker Alarm mode switch Low battery indicator Red LED Table mounting Modular jack PTT line Wall mounting screw holes Shaker jack Adaptor jack option Modular jack PTT line or for a second Amplicall10 connection batteries compartment 4 X AA REAR ...

Page 3: ...he compartment 2 Connect the telephone line cord of you phone at the Amplicall 10 3 Connect the RJ11 to RJ11 cable between the Amplicall and phone 4 Connect the adaptor option INSTALLATION AC adaptor option 230V UK plug Telephone plug Option Shaker ref SHAKCL_BLK ...

Page 4: ...n integral power on off switch To disconnect the power either switch off supply at the mains power socket or unplug the AC adaptor When installing the apparatus ensure that the mains power socket is readily accessible Telephone connection Voltages present on the telecommunication network are classified TNV 3 Telecommunication Network Voltage according to the EN60950 standard INSTALLATION ...

Page 5: ...owing positions 0 no alarm both strobe flasher and sound alarm selected both strobe flasher and shaker if connected selected both sound alarm and shaker if connected selected 2 VOLUME CONTROL SLIDE SWITCH Set the volume of the alarm sound or power on off 3 TONE CONTROL SWITCH 3 POSITIONS Set the tone of the alarm sound INSTALLATION ...

Page 6: ...lace the base cradle on the table Change The Battery The unit requires 4 AA batteries 1 Open the battery door 2 Insert four AA batteries into the compartment 3 Snap the battery compartment door back into place Note when the red indicator keep flashes this indicates battery low to indicate the batteries need replacing During replacement of the batteries disconnect all telephone line cords from the ...

Page 7: ... on When the power supply works normally the red low battery LED flashes automatically 1 Check if it is low battery 2 Turn off the power using the power off switch for 10 minutes and then turn back on When it is connected to the power adaptor or 4 batteries have been inserted however when there is an incoming call no rings 1 Check if it is connected to the power adaptor correctly 2 Check if the ba...

Page 8: ...ll rings normally or camera LED blinks normally when there is an incoming call but the shaker doesn t vibrate 1 Check if it is connected to the shaker correctly 2 Check if the shaker socket has been damaged 3 Check if the alarm mode selection switch position is correct INSTALLATION ...

Page 9: ...not an authorised Geemarc representative The Geemarc guarantee in no way limits your legal rights IMPORTANT YOUR RECEIPT IS PART OF YOUR GUARANTEE AND MUST BE RETAINED AND PRODUCEDIN THE EVENT OF A WARRANTY CLAIM Please note The guarantee applies to the United Kingdom only Declaration Hereby Geemarc Telecom SA declares that this product is in compliance with the essential requirements and other re...

Page 10: ... Please use one of the following disposal options Remove the batteries and deposit them in an appropriate WEEE skip Deposit the product in an appropriate WEEE skip Or hand the old product to the retailer If you purchase a new one they should accept it Thus if you respect these instructions you ensure human health and environmental protection For product support and help visit our website at www ge...

Page 11: ......

Reviews: