page | 17
The On-Screen Display
Using the HDMI and DVI to 3GSDI Scaler
Input ► Clean Aperture
Allows adjustment of the input signal position. The clean aperture parameters allow an
area within the production aperture to be defined. The minimum clean aperture size is
0 pixels by 0 lines. If the Non-Standard Sync option is enabled, then the input is set to
DFP sync.
Options
Description
Horizontal Size
Adjusts horizontal size
Vertical Size
Adjusts vertical size
Horizontal Position
Adjusts horizontal position
Vertical Position
Adjusts vertical position
Input ► Film Mode
When enabled, produces a progressive output signal from an interlaced input signal. This
feature automatically detects repeated field sequences present in interlaced signals, such
as 50 Hz or 60 Hz field sequences (no repeated fields), 60 Hz 3:2 pull-down, including
broken or edited sequence detection, 60 Hz 2:2: pull-down, 50 Hz 2:2 pull-down, static
frames, and multi-directional and inter-field motion.
Options
Description
Enable
Enables film mode (24 fps)
Disable
Disables film mode
Input ► Remote Channel
This option changes the IR channel to between 0 and 3. When the remote channel
of the Scaler is changed, the DIP switches on the IR remote must be changed to the
corresponding IR channel in order to operate the Scaler. See
Setting the IR Channel
for details on how to set the IR channel on the IR remote control unit.
Options
Description
0
Use IR channel 0
1
Use IR channel 1
2
Use IR channel 2
3
Use IR channel 3
(continued on next page)