background image

5

LED Power Indicator

This LED will become active once the included 5V DC power supply is properly 
connected between the sender and an open wall power socket.

IR Out (Blaster)

An optional IR transmitter/blaster (EXT-2IREMIT) connects to this output port. 
The IR blaster’s IR emitter will need to be placed on or near the IR receiver of a 
device for proper relaying of commands from the receiver.

3 DVI-D 

Input

This receptacle will accept a DVI Single-Link source device.

RS-232 Serial Communications Input

This port is capable of 2-way serial communication between RS-232 devices 
connected to the sender and receiver. This port can be connected to a 
computer’s serial communications port for interaction with a RS-232 serial 
communications device connected to the receiver.

RJ-45 Link Connector

This port is used to connect the sending and receiving units together for data 
traffi c. Use a CAT-5, CAT-5e or CAT-6 cable. When fi eld terminating cable 
please adhere to the TIA/EIA-568-B specifi cation (page 9).

Fiber Optic Connector (Multi-Mode SC Type)

This connector accepts 1 strand of SC terminated fi ber optic cable that will link 
the sending and receiving unit together. The DVI RS-232 over Fiber system will 
only accept multi-mode fi ber optic cabling.

Locking 5V DC Power Input

Connect the included 5V DC power supply to this input. The Power LED will 
become active when the 5V DC power supply has been properly connected 
to the unit and an open wall power socket. This receptacle features a locking 
connector for a secure connection.

SENDER PANEL DESCRIPTIONS

Summary of Contents for EXT-DVI-FO-141

Page 1: ...www gefen com f DVI RS 232 Over Fiber EXT DVI FO 141 User Manual ...

Page 2: ...Nordhoff St Chatsworth CA 91311 www gefen com support gefen com Notice Gefen Inc reserves the right to make changes in the hardware packaging and any accompanying documentation without prior written notice DVI RS 232 over Fiber is a trademark of Gefen Inc 2009 Gefen Inc All Rights Reserved All trademarks are the property of their respective companies ASKING FOR ASSISTANCE Rev A ...

Page 3: ...n Notes 3 Features 4 Sender Panel Layout 5 Sender Panel Descriptions 6 Receiver Panel Layout 7 Receiver Panel Descriptions 8 Connecting And Operating The DVI RS 232 Over Fiber 9 Network Cable Wiring Diagram 10 Specifications 11 Warranty ...

Page 4: ...efen DVI RS232 over Fiber is a perfect solution for extending and managing control systems touchscreen or digital signage applications at great distances The DVI RS232 sends DVI RS232 and IR signals up to 1000 feet using a single CAT5 and single SC fiber RS232 and IR signals are transmitted over a single CAT5 cable while the DVI signal is transmitted over a single SC fiber How It Works The DVI RS2...

Page 5: ...d CAT 5 CAT 5e or CAT 6 cables to operate the DVI RS 232 over Fiber Gefen recommends CAT 6 cabling for maximum performance For 1080p video maximum extension is 1000 feet 330 meters IR repeater functionality is only from the receiving unit to the sending unit IR data cannot be transmitted from the sending unit to the receiving unit 2 OPERATION NOTES ...

Page 6: ...ons Video is transmitted digitally over fiber optic cable for zero signal loss Supports resolutions up to 1080p 2K and 1920 x 1200 Supports DDWG standard for DVI compliant monitors Package Includes 1 DVI RS232 Sender 1 DVI RS232 Receiver 1 6 ft DVI Cable M M 1 6 ft RS232 Cable M F 2 5V DC Power Supply 1 User s Manual FEATURES ...

Page 7: ...4 Front Panel Back Panel 1 2 5 3 6 4 7 SENDER PANEL LAYOUT ...

Page 8: ...ions port for interaction with a RS 232 serial communications device connected to the receiver 5 RJ 45 Link Connector This port is used to connect the sending and receiving units together for data traffic Use a CAT 5 CAT 5e or CAT 6 cable When field terminating cable please adhere to the TIA EIA 568 B specification page 9 6 Fiber Optic Connector Multi Mode SC Type This connector accepts 1 strand o...

Page 9: ...6 Front Panel Back Panel 1 2 5 3 6 4 7 8 RECEIVER PANEL LAYOUT ...

Page 10: ...ecome active when the 5V DC power supply has been properly connected to the unit and an open wall power socket This receptacle features a locking connector for a secure connection 6 Infrared IR Receiver Extension Port This port will accept an optionally purchased IR extension cable Gefen part EXT RMT EXTIR This is useful for installations where the IR receiver located on the front panel Item 2 on ...

Page 11: ...ver Fiber sending and receiving units together using one user supplied SC terminated multi mode fiber optic cable and one CAT 5 CAT 5e or CAT 6 cable NOTE If field terminating network cable please adhere to the TIA EIA568B specification Please see page 9 for more information 5 Connect the DVI D capable output device to the DVI output port of the DVI RS 232 over Fiber receiving unit using a user su...

Page 12: ...pected results and reduced performance CAT 5 CAT 5e and CAT 6 cabling comes in stranded and solid core types Gefen recommends using solid core cabling CAT 6 cable is also recommended for best results Each cable run must be one continuous run from one end to the other No splices or use of punch down blocks Pin Color 1 Orange White 2 Orange 3 Green White 4 Blue 5 Blue White 6 Green 7 Brown White 8 B...

Page 13: ...00 DVI I O Connectors DVI I 29 pin female digital only RS232 Input Connector DB 9 female RS232 Output Connector DB 9 male Power Supply 5V DC Power Consumption 20 Watts max Link Connector RJ 45 Video Link Connector SC Serial Communication Standard RS 232 standards Dimensions 4 75 W x 1 125 H x 3 375 D Shipping Weight 5 lbs SPECIFICATIONS ...