42
50950260/AP1216
the parking brake switch is ON.
Note:
When the key is turned to the RUN position, an indicator lamp will light on
the instrument panel and a chirp will sound momentarily to remind users to
fasten the seatbelt
4.
Turn the key to the START position.
Note:
If temperature is below 32° F (0° C), see Cold-Starting Procedure, on page
46.
Important:
Do not engage the starter for longer than 15 seconds at a time.
Longer use can overheat and damage the starter. If the engine fails to start within
15 seconds, return the key to the OFF position or check for engine error codes.
Allow the starter to cool for 20 seconds and repeat step 4.
After the engine starts, allow a five minute low idle warm-up period before oper-
ating the controls.
Important:
Avoid extended engine idling after the engine reaches normal oper-
ating temperature to prevent frequent DPF regenerations. If the indicator
warning lamps do not go off, stop the engine and investigate the cause.
Cold-Starting
If the temperature is below 32° F (0° C), the following is recommended to make
starting the engine easier:
Replace the engine oil with API-CJ-4/SAE 5W-30 oil as recommended by
the viscosity chart;
Make sure the battery is fully charged;
Install a block heater on the engine.
Let the engine run for a minimum of five minutes to warm the engine and
hydraulic fluid before operating the loader. A block heater is recommended for
starting in temperatures of 14° F (-10° C) or lower. See your dealer for heater
options.
Cold Starting Procedure
Do not use starting fluid (ether) with preheat
systems. An explosion can result which can
cause engine damage, injury or death.
1. Turn the key to the RUN position. If the preheat light on the right instrument
panel comes on, wait for this symbol to go out.
2.
Immediately turn the key to the START position.
3.
If engine does not start, return key to OFF position and repeat steps 1 and 2.
Important:
During cold start conditions, the recommended limit of continuous
starter engagement is 15 seconds and the starter must never be energized for
WARNING
Summary of Contents for R105 (EU)
Page 64: ...60 50950260 AP1216 Notes...
Page 78: ...74 50950260 AP1216 Engine Diagnostic Chart DPF Models...
Page 79: ...50950260 AP1216 75 Engine Diagnostic Chart DPF Models cont...
Page 80: ...76 50950260 AP1216 Engine Diagnostic Chart DPF Models cont...
Page 81: ...50950260 AP1216 77 Engine Diagnostic Chart DPF Models end...
Page 102: ...98 50950260 AP1216 Maintenance Log Date Hours Service Procedure...
Page 103: ...50950260 AP1216 99 Maintenance Log Date Hours Service Procedure...
Page 104: ...100 50950260 AP1216 Maintenance Log Date Hours Service Procedure...
Page 116: ...112 50950260 AP1216 NOTES...