Electrical System
Problem
Possible Cause
Remedy
Work lights not
functioning
properly.
Single light doesn’t work:
Light bulb burned out, faulty
wiring.
Check and replace light bulb
as needed. Check wiring
connection to light.
No lights at all; 20 ampere
breaker tripped.
Check circuit and locate
trouble before replacing fuse.
Faulty light switch or poor
ground.
Replace light switch. Check
ground wire connections.
Lift/Tilt and/or
drive lock
solenoids do not
work.
Wiring to solenoids
disconnected or faulty.
Troubleshoot circuit, repair.
Restraint bar or seat switch
malfunction.
Contact your dealer.
Faulty solenoid valve coil.
Contact your dealer.
Faulty hydraulic solenoid
relay in instrument panel.
Contact your dealer.