11
www.geiger.de
EN
EN
observing the dangerous goods regulations for Li-Ion batteries of less than 100Wh. In case of
shipment by third parties (e.g.: air transport or forwarding), special requirements for packaging
and labelling must be observed. A dangerous goods expert must be consulted when preparing
the package. Only send batteries if the housing is undamaged. Tape open contacts and pack
the battery so that it does not move in the packaging. Please also observe any further national
regulations.
11. LED indication
Depending on the delivery, the LED display for outdoor use (M56F157)
or the LED display for indoor use (M56F158) is supplied.
The LED display for indoor use must be connected with the cable to a
junction box (not included in scope of delivery) by a qualified electrician.
The length of the cable should not exceed 100 meters.
For both types, three different coloured LED´s (green/yellow/red) indicate
the different states of the system:
Functionality / LED display:
Permanent light signals (permanently lit LEDs)
Green Yellow
Red
Significance
P
All system functions OK / manual operation
P
Reference run
P
P
Learning run upper end position
P
P
Learning run lower end position
P
P
Shutdown by overload protection
Flashing signals (simultaneous flashing of various colour LEDs)
p
Freezing protection activated (≤ 3°C)
p
Defective battery / replace battery
p
No mains voltage
p
p
Ambient temperature too high (battery) (≥ 45°C)
p
p
Ambient temperature too low (battery) (≤ 0°C)
p
p
Battery has reached critical level
p
p
p
Fire alarm / wire break
Flashing signals (alternate flashing of various colour LEDs)
p
p
Deep discharge
p
p
Device temperature too high (only fire alarm is triggered)
(≥ 60°C)
Flashing signals (moving lights of various colour LEDs)
p
p
p
Emergency manual operation (only to lower end stop)
Permanent light signals and flashing signals
(combination of lit and flashing LEDs)
P
p
Minimum operating temperature not met (≤ -10°C)
Operating mode: Programming mode (commissioning):
The unit will be learned through an unlocked switch.
f
See point „Commissioning“
The green/yellow or green/red LEDs light depending on the direction of travel.
Operating mode: Manual operation
After teaching, a blocked switch is used (standard operation). The blind is opened/closed via
the locked switch (manual operation or emergency manual operating).
The green LED lights up.
blue
brown
blac
k
green
grey
yellow
brown
whit
e
LED (inside)