18
Gerhard Geiger GmbH & Co. KG | 100W1590
0519
V001
en
EN
EN
23. Technical data
Technical data GJ5606 AE...
Motor
Voltage
100 ..230 V 50/60 Hz
Current
35 mA (max. load current)
Power
8 W
Couple
2 x 3 Nm
Normal operating torque
22 1/min
Emergency operation torque
27 1/min
Protection class
IP 44
Limit switch range
> 200 rotations
Operating mode
S2 4 min
Dimensions (without coupling)
346 mm
Diameter
55 mm
Gewicht
1,60 kg
Ambient temperature / humidity
Operation: T = -10°C .. +60°C / H max. 90%
Storage : T = -15°C .. +45°C / H max. 50%
Electronic control
Dimensions
220 mm
Diameter
55 mm
Weight (without battery)
0,30 kg
Battery
Type
LiFePo4
Capacity
14,08 Wh / 1,1 Ah
Charging temperature range
0°C to 45°C
Operating time in case of mains voltage
failure (UPS operation)
> 4 min. (battery mode)
Battery buffer
> 6 Wh (incl. reserve) at 12 VDC
> 0,5 Ah (500mAh)
Weight
0,20 kg
Indoor LED display
Dimensions
53 x 13 x 8 mm (L x H x B)
Outdoor LED display
Dimensions
57 x 17 x 17 mm (L x H x B)
Subject to technical modifications. Please find information to the ambient
temperature range of our GEIGER motors under www.geiger.de
Note: The drive is always operated via the battery backup.
The battery is designed in such a way that at all times (even at 50% capacity) the drive is
operational at least 4 minutes.