7
www.geiger.de
EN
EN
8. Setting of the end stops
I
The setting of the motor GF56..e5 can be realized with any switch
allowing simultaneous UP and DOWN commands.
Part-Nr. / GEIGER setting switch
M56K144
With Hirschmann STAK3 connector (D)
M56F150
With Hirschmann STAK3 connector (CH)
M56F151
With terminal (D)
M56B265
Adaptation cable with terminal and STAS3
M56E399
Adaptation cable with STAK3 and open cable ends
Readjustment of the end stops
The readjustment of the end stops can be carried out at any time in accordance with the
instructions given below. If there is no running of the blind by the operation points 3 and 5 the
end stops have kept the same position as before.
Overload recognition
The overload recognition is adapted to the given torque (+ safety margin) of the Venetian blind
system by carrying out the complete adjustment procedure. The blind must be moved by steps
3 and 5.
Setting GSI56..e5
I
The order of the adjustment process must be strictly adhered to and
the adjustment must always be completely implemented (all steps).
1. Connect the setting switch to the GSI56..e5 and then plug in power supply
2. Press the programming key till the LED flashes (1 flash light, break, 1 flash light, break,…)
then release the programming key.
3. Setting of the lower end position
: press the direction keys to exactly run the GSI56..e5 to
the desired lower end position.
4. Press the programming key till the LED flashes (2 flash lights, break, 2 flash lights, break,…)
then release the programming key
5. Setting of the upper end position:
press the direction keys to exactly run the GSI56..e5 to
the desired upper end position.
6. Press the programming key till the LED keeps lighting. The adjustment procedure is
completed.
I
When using an external setting switch, the UP and DOWN keys
must be activated simultaneously – instead of the programming key.
Instead of the lighting up of the LED, the motor reacts with a short
back and forth movement.