background image

13

Hours
To change the displayed value, it is necessary, having pressed and keeping the key hidden by the UBC 400 sign, to quickly press key «_» (for increase) or key „_“ (for
decrease). These keys should be pressed until the necessary value

Minutes
To change the displayed value, it is necessary, having pressed and keeping the key hidden by the UBC 400 sign, to quickly press key «_» (for increase) or key „_“ (for
decrease). These keys should be pressed until the necessary value

Date - day
To change the displayed value, it is necessary, having pressed and keeping the key hidden by the UBC 400 sign, to quickly press key «_» (for increase) or key „_“ (for
decrease). These keys should be pressed until the necessary value

Date - month
To change the displayed value, it is necessary, having pressed and keeping the key hidden by the UBC 400 sign, to quickly press key «_» (for increase) or key „_“ (for
decrease). These keys should be pressed until the necessary value

Date - year
To change the displayed value, it is necessary, having pressed and keeping the key hidden by the UBC 400 sign, to quickly press key «_» (for increase) or key „_“ (for
decrease). These keys should be pressed until the necessary value

Uhrzeit Datums- Jahr: Jah 2004
Bei Änderung des angezeigten Wertes muss die mittlere unsichtbare Taste gedrückt gehalten und für + ( höherer Wert ) die Pfeil nach oben Taste, oder für - (niedriger
Wert ) die Pfeil nach unten Taste zusätzlich kurz gedrückt werden. Die Tasten solange betätigen bis der angezeigte Wert stimmt.

The following menu item is selected by pressing
key „up“ with pressed key „down“

12.4  Automatic emergency device BLC 100 (option)
12.4.1 Safety 

rules

Installation must be charged only to skilled electricians. Do not begin to work with the given equipment without carefully studying all documentation applied to it. The given safety rules and other instructions
of the manufacturer should be executed every time when working with this device. If you have no instructions on work with the equipment, appeal to a representative of the manufacturer. Ask immediate
dispatch of the necessary documentation to address of the responsible for the safety use of industrial electronics. These safety instructions must be also attached when selling, hiring, and/or transferring com-
ponents.
Warning! Products of industrial electronics must be commissioned only by specialists with sufficient knowledge in electrical engineering, generators, and motor equipment.
Necessarily study warnings of the dangerous factors included in the documentation.
Metallwarenfabrik is not responsible for damage arisen due to failure to comply with warnings contained in this Operation Manual.
If changes that are not indicated in this Manual are introduced into the device, guarantees are automatically cancelled. The below safety instructions should be necessarily studied and fulfilled before com-
missioning the electric plant in order to prevent injuries and/or material damage. These safety instructions should be carried out constantly.

12.4.1.1  Purpose application

An industrial electronic device BLC 100 Geko is intended only for application in electric plants. All electric plants should be certificated by their manufacturers for application in certain areas and checked
on both resistance to overloads and operational reliability. The manufacturer of a device has to provide the corresponding safety measures. Before commissioning, the device should pass comprehensive
tests for conformity to the technical and local requirements for it, as well as to the safety rules concerning the area of its application.

12.4.1.2  CE marking

The industrial electronic device BLC 100 is intended for application in the structure of equipment. For this reason, it is offered to manufacturers of equipment only as a completing product. Thus, the device is
not subject to CE marking.

Summary of Contents for 4401 E -AA/HEBA

Page 1: ...fax 49 7267 806100 www metallwarenfabrik com 4401 E AA HHBA 4401 E AA HEBA 5401 ED AA HHBA 5401 ED AA HEBA 6401 ED AA HHBA 6401 ED AA HEBA 7401 ED AA HHBA 7401 ED AA HEBA 7401 E AA HHBA 7401 E AA HEBA...

Page 2: ...2...

Page 3: ...Fuel cock Sockets Silent economic fast start switch Starting handle Ignition key switch Drain plug Oil filler neck Oil level indicator Filler neck of the fuel tank Ground screw Air filter Silencer Fu...

Page 4: ...y On the contrary electric power is often necessary urgently by inquiry similarly to the circuits of power supplying enterprises By using the Geko Silent Economic mode the rotation frequency of the en...

Page 5: ...ric test requirements to waste gases in the world accep ted in California California Air Resources Board for 2006 Automatic stop at low oil level OHV reduces the consumption of oil by 50 reduces the c...

Page 6: ...required short circuit current of the generator is insufficient for the circuit breaker of an available consumer or the wire resistance is more than 1 5 M it is necessary to provide protection measur...

Page 7: ...dicator 2 Insert the oil level indicator into the filler neck but do not screw 3 If the oil level is low it is recommended to add oil up to the edge of the filler neck It is necessary to use oil for f...

Page 8: ...the fuel cock to the ON position 2 If necessary close the air valve At hot start the valve opens automatically Warning Do not use the valve if the engine is hot or the tempera ture of air is high Fue...

Page 9: ...Warning When the cord retracts back do not release the handle It should be moved accurately in order to pre vent the damage of the starting device Electric start all types For the start by the electri...

Page 10: ...FFS 100 for remote start and stop of the electric plant option The device is made in the form of a compact module Geko SMD Due to the small sizes of the transmitter a user can constantly carry it wit...

Page 11: ...r sig nals are processed by a microprocessor The parameter is chosen by arrow keys Change of the parameters of maintenance periodicity the calibrations of voltage and current and the reset of the oper...

Page 12: ...he first maintenance i e after this time the first maintenance must be car ried out 2 500h Operating time remaining to the second maintenance i e after this time the second maintenance must be carried...

Page 13: ...ules and other instructions of the manufacturer should be executed every time when working with this device If you have no instructions on work with the equipment appeal to a representative of the man...

Page 14: ...s lead to danger to life the possibility of heavy physical injuries or material damage Attention If a BLC equipped genset will be started with disconnected battery or reverse connected battery a 2A fu...

Page 15: ...ion of the electric plant with BLC 100 See electric schemes 100107 100108 and 100132 The circuit is connected to a head on the face panel of the distribution box Output voltage is taken through a CEE...

Page 16: ...t it is necessary to check its serviceability by the test button of the protective circuit breaker If the circuit breaker is not triggered it is forbidden to use the electric plant See electrical conn...

Page 17: ...tional The additional fuel tank enable extra long running times of the genset A mechanical engine driven pump deliver the fuel from the lower tank to the careburator The standard 20l tank remain usabl...

Page 18: ...turn short circuit in stator replace the stator by a new one Overcurrent circuit breaker Actuate or replace the circuit is actuated or defect breaker Insufficient rotation speed run up to rated speed...

Page 19: ...the authorized workshops in the Appendix Mount only original components when replacing them 14 Scheduled maintenance Before the beginning of maintenance works the engine should be stopped 14 1 Electr...

Page 20: ...Remove the ignition wire from the spark plug Unscrew the spark plug by a spark plug wrench If necessary clean electrodes by a brass brush If the spark plug is damaged replace it Check the interelectro...

Page 21: ...lywheel again turn the central nut Unscrew four screws with six sided heads drawing moment 7 3 N m and remove the fan case Weaken the clamp and remove the fan propeller Unscrew screws and remove the b...

Reviews: