18
13. Possible faults and ways of their elimination
No.
Faults
Origin
Elimination
1
The engine can not be started
Not enough oil is filled or
Check the oil level, if necessary
the gas-electric generating set is
refill the engine oil or provide
situated on an inclined ground
an even surface
2
The gas-electric generating set
Engine oil in the combustion
Remove the spark plug and
can not be started
chamber (because of intensive
pull through the engine with a reversing starter 3-4 times.
tilting or falling of the aggregate)
Clean the carburettor and the air filter.
Mechanical damages in the range
Maintenance or replacement
of the reversing starter or
through a new spare part
blower hood
3
The gas-electric generating set
Capacitor is defect
Replace the capacitor
does not deliver enough voltage
interturn short circuit in stator
replace the stator by a new one
Overcurrent circuit breaker
Actuate or replace the circuit
is actuated or defect
breaker
Insufficient rotation speed
run up to rated speed, idle
of the engine
running 3180 1/min, max. 250 V
The air filter and/or the
Clean the component or insert
carburettor is contaminated
a new filter set
4
No or not enough voltage
Insufficient rotation speed of the
The engine must be set to the
after loading
engine or the speed controller
rated speed of 3180 1/min,
is not serviceable
max. 250 Volt in an authorized
workshop
Climatic influences reduce
Do not load the gas-electric
the power of the gas-electric generating set
generating set with the rated speed, see operating instructions of the engine
5
Excessive voltage of the gas-electric
Excessive speed of the engine generating set
Adjust the rated speed of the engine, however max. 253 Volt
6
Generator gets inadmissible warm
Overloading of the gas-electric generating set
Switch off some consumers