23 / 32
1434 µPos
3.3
Mounting the external travel
sensor (only for version with
remote mounting)
4
3
1
Valve with external travel sensor
● Fix positioner
1
at a suitable location.
The GEMÜ 1446 00 ZMP
mounting bracket (to be ordered
separately) can be used to do
this.
● Assemble the travel sensor (see chapter
3.1 “Assembling the travel sensor”).
l
Mount travel sensor
4
to actuator
3
and
fi x it to travel sensor
4
using a suitable
open-end wrench SW27.
SW27
3
4
Travel sensor and actuator
Travel sensor mounted on actuator
3.4
Mounting the positioner using
a mounting bracket
The positioner is mounted with a
mounting bracket when valves are
used which have larger position
changes than the integrated travel
sensor on the positioner can detect.
4
3
1
5
Valve with mounting bracket
● Assemble the travel sensor (see chapter
3.1 “Assembling the travel sensor”).
● Place mounting bracket
5
with travel
sensor
4
on actuator
3
and fi x it to travel
sensor
4
using a suitable open-end
wrench SW27.
● Fix positioner
1
to mounting bracket
5
.
3
4
1
5