Electrical data
OptiFlex A1 (AS07)
Main input voltage
100-240 VAC
Device input voltage
100-240 VAC
(for gun control units)
200-240 VAC
(for axis control units)
Frequency 50/60
Hz
Input power (sum of the power values of
all control units)
40 VA per gun control unit
1.1 kVA per axis control unit
Protection type (control units)
IP54
Temperature range (operation)
10-40°C / 50-104 °F
Pneumatic data
OptiFlex A1 (AS07)
Min. input pressure
6 bar / 87 psi
Max. input pressure
8 bar / 116 psi
Max. water vapor content of the
compressed air
1.3 g/m³
Max. oil vapor content of the compressed
air
0.1 mg/m³
Total air consumption
8 Nm³/h per gun (plus powder
hopper air requirement)
Dimensions
OptiFlex A1 (AS07)
Width 600
mm
Depth 697
mm
Height
max. 1838 mm