Commissioning
•
15
NOTE:
The OptiFlex A1 powder coating control system may can be
switched on only if the booth is in operation!
If the booth switches off, the control system must also switch off!
Compressed air
-
The OptiAir pneumatic-fluidizing unit is always used as
main compressed air input, compressed air distributor
and for fluidizing air monitoring
-
The OptiFlex A1 Control system just requires a
connection to the main compressed air system
-
The compressed air values are evident in the technical
data section
Air requirement with increased powder output
The control system offers the possibility to work with increased powder
output in sufficiently dimensioned compressed air systems. The pressure
regulator on the filter unit is preset by factory to
5.5 bar
with an air flow of
5 m
3
/h per control unit
. If another value is set on the pressure regulator,
then the
system parameter 2
on
each OptiStar
Control unit
needs to be
adjusted according to the following instructions:
NOTE:
In order to achieve the largest accuracy, the air pressure is to be set
during operation by average compressed air consumption!
> 5 s
Compressed air setting - parameter setting
OptiStar CG08 automatic gun control unit
Conversion bar-psi
5.5 bar = 80 psi
6.0 bar = 87 psi
6.5 bar = 94 psi
5.5 6.0
6.5