V
04/07
OptiFeed B Fresh powder system
Maintenance
•
23
Maintenance
OptiFeed B Fresh powder system
Note:
Regular and conscientious maintenance increases the service life of
the fresh powder system and ensures a longer, more constant con-
veying performance!
Daily maintenance
-
Empty the powder hose by removing the fluidizing/suction
unit from the powder container when the conveying is acti-
vated
Weekly maintenance
-
Visual check of the pinch valves in the PP05 Powder pump
for possible damages
Note:
For further information, see the OptiFeed PP05 Powder pump oper-
ating manual!
Longer standstill of the fresh powder system
-
Interrupt the power supply/remove the mains plug
-
Turn off the compressed air main supply
-
Clean the OptiFeed B Fresh powder system thoroughly
Cleaning the fluidizing/suction unit
-
Remove the fresh powder pump from the fluidizing/suction
unit
-
Remove the fluidizing/suction unit
-
Clean the fluidizing/suction unit with compressed air. Blow off
the suction tube also with compressed air
-
Visual check of the fluidizing/suction unit for possible dam-
ages