V
04/07
4
•
General safety regulations
OptiFeed B Fresh powder system
use. The OptiFeed B Fresh powder system should only be used,
maintained and started up by trained personnel, who are in-
formed about and are familiar with the possible hazards involved.
4. Start-up (i.e. the execution of a particular operation) is forbidden
until it has been established that the OptiFeed B Fresh powder
system has been set up and wired according to the guidelines for
machinery (98/37 EG). EN 60204-1 (machine safety) must also
be observed.
5. Unauthorized modifications to OptiFeed B Fresh powder system
exempts the manufacturer from any liability from resulting dam-
age.
6. The relevant accident prevention regulations, as well as other
generally recognized safety regulations, occupational health and
structural regulations are to be observed.
7. Furthermore the country-specific safety regulations must be ob-
served.
Explosion protection
Protection type
Temperature class
II 3 D
IP54 T6
Technical safety regulations for stationary electro-
static powder spraying equipment
General information
The powder spraying equipment from ITW Gema is designed with safety
in mind and is built according to the latest technological specifications.
This equipment can be dangerous if it is not used for its specified pur-
pose. Consequently it should be noted that there exists a danger to life
and limb of the user or third party, a danger of damage to the equipment
and other machinery belonging to the user and a hazard to the efficient
operation of the equipment.
1. The powder spraying equipment should only be started up and
used once the operating instructions have been carefully studied.
Improper use of the controlling device can lead to accidents, mal-
function or damage to the control itself.
2. Before every start-up check the equipment for operational safety
(regular servicing is essential)!
3. Safety regulations BGI 764 and VDE regulations DIN VDE 0147,
Part 1, must be observed for safe operation.
4. Safety precautions specified by local legislation must be ob-
served.
5. The plug must be disconnected before the machine is opened for
repair.
6. The plug and socket connection between the powder spraying
equipment and the mains network should only be taken out when
the power is switched off.
7. The connecting cable between the controlling device and the
spray gun must be set up so that it cannot be damaged during