Rev. 00 09/16
26
Operation
OptiFlex 2 F
Setting the fluidization
The powder fluidization depends on the powder type, the air humidity and
the ambient temperature. Fluidizing and vibration start by switching on the
control unit.
1.
Press the
key
The second display level will be shown
2.
Adjust the fluidizing air with the keys
T5/T6
– If in this display level is no operation for 3 seconds, the device
switches back to the first display level
3.
Check fluidization of the powder in the powder container
– The powder should only be touched gently, but should be
"cooked" regularly and is also to be stirred using a rod
CAUTION
Large dust formation possible!
If the fluidization has been incorrectly adjusted, then the coating
powder can create a dust cloud capable of causing respiratory
problems.
► Adjust the fluidization correctly.
4.
Point the gun into the booth (not at the object to be coated), press
the gun trigger and visually check the powder output
5.
Check whether everything is functioning correctly
6.
Coating
7.
Adjust the coating parameters as necessary
8.
Activate the rinsing function periodically
Summary of Contents for OptiFlex 2 F
Page 12: ...Rev 00 09 16 12 Safety OptiFlex 2 F ...
Page 20: ...Rev 00 09 16 20 Assembly Connection OptiFlex 2 F ...
Page 32: ...Rev 00 09 16 32 Operation OptiFlex 2 F 29 30 ...
Page 34: ...Rev 00 09 16 34 Decommissioning Storage OptiFlex 2 F ...
Page 48: ...Rev 00 09 16 48 Fault clearance OptiFlex 2 F ...
Page 52: ...Rev 00 09 16 52 OptiSelect GM03 OptiFlex 2 F ...
Page 59: ...Rev 00 09 16 OptiFlex 2 F Maintenance Repairs 59 Replacing the insert sleeve 1 2 3 4 ...
Page 60: ...Rev 00 09 16 60 Maintenance Repairs OptiFlex 2 F ...
Page 62: ...Rev 00 09 16 62 Fault clearance OptiFlex 2 F ...
Page 65: ...Rev 00 09 16 OptiFlex 2 F Spare parts list 65 OptiFlex 2 F Spare parts fig 14 ...
Page 82: ...Rev 00 09 16 82 Spare parts list OptiFlex 2 F OptiFlow IG06 spare parts fig 24 ...
Page 84: ...Rev 00 ...