Rev. 00 09/16
OptiFlex 2 F
Fault clearance
39
Fault clearance
Prior to any troubleshooting measures, always check whether the
equipment parameter (P00) as configured in the control unit is
correct
► See operating instructions for the OptiStar CG13 manual gun
control unit, Chapter "Initial Start-up
– Setting Equipment Type"!
Incident
Causes
Corrective action
H11 (Help code on control
unit)
Gun not connected
Connect the gun
Gun plug or gun cable defective
Contact local Gema
representative
Remote control on powder gun
defective
Contact local Gema
representative
Control unit displays remain
dark, although the control
unit is switched on
Control unit is not connected to
the mains
Connect the equipment with the
mains cable
Power pack fuse defective
Replace the fuse
Power pack defective
Contact local Gema
representative
Gun LED remains dark,
although the gun is triggered
High voltage adjustment is set
too low
Increase high voltage
Gun plug or gun cable defective
Contact local Gema
representative
LED on gun defective
Contact local Gema
representative
Powder does not adhere to
object, although the gun is
triggered and sprays powder
High voltage and current
deactivated
Check the high voltage and
current setting
High voltage cascade defective
Contact local Gema
representative
The objects are not properly
grounded
Check the grounding
The gun does not spray
powder, although the control
unit is switched on and the
gun trigger is pressed
Compressed air not present
Connect the equipment to the
compressed air
Injector or nozzle on the
injector, powder hose or
powder gun clogged
Clean the corresponding part
Insert sleeve in the injector is
clogged
Clean/replace
Fluidization not running
see below
Summary of Contents for OptiFlex 2 F
Page 12: ...Rev 00 09 16 12 Safety OptiFlex 2 F ...
Page 20: ...Rev 00 09 16 20 Assembly Connection OptiFlex 2 F ...
Page 32: ...Rev 00 09 16 32 Operation OptiFlex 2 F 29 30 ...
Page 34: ...Rev 00 09 16 34 Decommissioning Storage OptiFlex 2 F ...
Page 48: ...Rev 00 09 16 48 Fault clearance OptiFlex 2 F ...
Page 52: ...Rev 00 09 16 52 OptiSelect GM03 OptiFlex 2 F ...
Page 59: ...Rev 00 09 16 OptiFlex 2 F Maintenance Repairs 59 Replacing the insert sleeve 1 2 3 4 ...
Page 60: ...Rev 00 09 16 60 Maintenance Repairs OptiFlex 2 F ...
Page 62: ...Rev 00 09 16 62 Fault clearance OptiFlex 2 F ...
Page 65: ...Rev 00 09 16 OptiFlex 2 F Spare parts list 65 OptiFlex 2 F Spare parts fig 14 ...
Page 82: ...Rev 00 09 16 82 Spare parts list OptiFlex 2 F OptiFlow IG06 spare parts fig 24 ...
Page 84: ...Rev 00 ...