Rev. 00 09/16
56
OptiFlow IG06
OptiFlex 2 F
Powder volume setting for OptiFlow Injector
In order to set the ideal powder volume on the OptiStar gun control unit, it
is recommended to select the firmness of the powder cloud or the total air
first. As guide values for different powder hoses, the following can be
assumed:
–
Powder hose 74 type, Ø 10 mm,
3-5 m³/h
–
Powder hose 66 type, Ø 11 mm,
4-5 m³/h
According to the prevailing conditions (powder, powder hose layout, the
parts to be coated) a low to lowest total air can also be set with the
standard hose 74 type, Ø 10 mm.
If a very large powder output is required, it is recommended to select a
larger powder hose internal diameter (Ø 12 mm).
It should to be noted, that if irregular or pumping conveying
occurs, as a rule, the total air is set too low!