Fault clearance
OptiFlex Pro BN
Incident
Causes
Corrective action
Pressure valve in the control
unit defective
Replace
Solenoid valve in the control
unit defective
Replace
No conveying air:
– Throttle motor defective
– Solenoid valve defective
Contact local Gema
representative
Front plate defective
Contact local Gema
representative
Gun achieving only poor
spray profile
Total air incorrectly configured
Increase the powder quantity
and/or total air volume on the
control unit
Bend or damage to air lines to
injector
Check air lines to injector
Insert sleeve in the injector
worn or not inserted
Replace or insert it
Fluidization not running
see below
No electrode rinsing air
Rinsing air throttle motor
defective
Contact local Gema
representative
The powder is not fluidized
Compressed air not present
Connect the equipment to the
compressed air
Fluidizing air is set too low on
the control unit
Set the fluidizing air correctly
Throttle motor defective
Contact local Gema
representative
Stirrer motor not functioning
Motor/condenser broken
Contact local Gema
representative
Motor cable not plugged in
plug in
Summary of Contents for OptiFlex Pro BN
Page 12: ...Rev 01 08 20 12 Safety OptiFlex Pro BN ...
Page 19: ...Rev 01 08 20 OptiFlex Pro BN Product description 19 Rating plate fig 4 ...
Page 20: ...Rev 01 08 20 20 Product description OptiFlex Pro BN ...
Page 24: ...Rev 01 08 20 24 Assembly Connection OptiFlex Pro BN ...
Page 36: ...Rev 01 08 20 36 Operation OptiFlex Pro BN ...
Page 44: ...Rev 01 08 20 44 Maintenance Repairs OptiFlex Pro BN ...
Page 48: ...Rev 01 08 20 48 Disposal OptiFlex Pro BN ...
Page 51: ...Rev 01 08 20 OptiFlex Pro BN Spare parts list 51 OptiFlex Pro BN Spare parts fig 11 ...
Page 57: ...Rev 01 08 20 OptiFlex Pro BN Spare parts list 57 ...
Page 58: ......
Page 60: ...Rev 01 ...