Rev. 00 03/19
OptiFlex Pro F Spray
Operation
31
Description
Presetting
Powder output
60 %
Total air
4.0 Nm³/h
High voltage
80 kV
Spray current
20 µA
Electrode rinsing air
0.1 Nm³/h
Fluidizing air
1.0 Nm³/h (for device type F)
0.1 Nm³/h (for device type B and S)
Setting powder output and powder cloud
The powder output depends on the selected powder output (in %), and
the powder cloud on the selected total air volume.
The AP01 Application pump should be operated with powder at
least 1/2 hour after starting up.
– After the running-in of the filter elements a stable powder output
value will be reached.
As a factory default value, a powder rate of 60% and a total air
volume of 4 Nm³/h are recommended.
– If values are entered that the gun control unit cannot implement,
then the operator is informed of this by a blinking in the relevant
display and a temporary error message!
Setting the total air volume
1.
Adjust the total air volume on the gun control unit with the
T3/T4
keys
– Adjust the total air volume according to the corresponding coating
requests
correct powder cloud
too little total air
Summary of Contents for OptiFlex Pro F
Page 6: ......
Page 14: ...Rev 00 03 19 14 Safety OptiFlex Pro F Spray ...
Page 22: ...Rev 00 03 19 22 Product description OptiFlex Pro F Spray ...
Page 26: ...Rev 00 03 19 26 Assembly Connection OptiFlex Pro F Spray ...
Page 40: ...Rev 00 03 19 40 Operation OptiFlex Pro F Spray ...
Page 50: ...Rev 00 03 19 50 Disposal OptiFlex Pro F Spray ...
Page 53: ...Rev 00 03 19 OptiFlex Pro F Spray Spare parts list 53 OptiFlex Pro F Spray Spare parts fig 10 ...
Page 58: ......
Page 60: ...Rev 00 ...