Fault clearance
OptiFlex Pro F Spray
Incident
Causes
Corrective action
Solenoid valve in the control
unit defective
Replace
No conveying air:
– Throttle motor defective
– Solenoid valve defective
Contact local Gema
representative
Front plate defective
Contact local Gema
representative
Gun achieving only poor
spray profile
Total air incorrectly configured
Increase the powder quantity
and/or total air volume on the
control unit
Bend or damage to air lines to
application pump
Check air lines to application
pump
Pinch valve hose in the
application pump worn
Replace
Fluidization not running
see below
No electrode rinsing air
Rinsing air throttle motor
defective
Contact local Gema
representative
The powder is not fluidized
Compressed air not present
Connect the equipment to the
compressed air
Fluidizing air is set too low on
the control unit
Adjust the fluidization correctly
Throttle motor defective
Contact local Gema
representative
Powder flows out of the
powder hopper
Airmover pressure incorrectly
set
Adjust
Summary of Contents for OptiFlex Pro F
Page 6: ......
Page 14: ...Rev 00 03 19 14 Safety OptiFlex Pro F Spray ...
Page 22: ...Rev 00 03 19 22 Product description OptiFlex Pro F Spray ...
Page 26: ...Rev 00 03 19 26 Assembly Connection OptiFlex Pro F Spray ...
Page 40: ...Rev 00 03 19 40 Operation OptiFlex Pro F Spray ...
Page 50: ...Rev 00 03 19 50 Disposal OptiFlex Pro F Spray ...
Page 53: ...Rev 00 03 19 OptiFlex Pro F Spray Spare parts list 53 OptiFlex Pro F Spray Spare parts fig 10 ...
Page 58: ......
Page 60: ...Rev 00 ...