Rev. 00 03/19
44
Maintenance / Repairs
OptiFlex Pro F Spray
If in disuse for several days
1.
Separate from power mains
2.
Clean the coating equipment
3.
Turn off the compressed air main supply
Powder hose rinsing
If longer downtimes take place, the powder hose has to be cleaned.
Procedure:
1.
Remove the powder hose from the hose connection on the
application pump
2.
Point the gun into the booth
3.
Blow through the hose manually with a compressed air gun
4.
Connect the powder hose again to the hose connection on the
application pump
Gun maintenance
The gun is designed to require only a minimum amount of maintenance.
1.
Clean the gun with dry cloth, see chapter "Maintenance"
2.
Check connection points to powder house.
3.
Replace the powder hoses, if necessary.
Maintenance of the filter unit
The filter unit on the manual coating equipment measures and cleans the
compressed air. This is where the equipment's main compressed air
connection is located.
Replacing the filter element
1.
Unscrew the filter glass on the filter unit
2.
Remove the complete filter element
fig. 9
3.
Replace the filter element
4.
Clean the filter glass on the inside and install it again
Summary of Contents for OptiFlex Pro F
Page 6: ......
Page 14: ...Rev 00 03 19 14 Safety OptiFlex Pro F Spray ...
Page 22: ...Rev 00 03 19 22 Product description OptiFlex Pro F Spray ...
Page 26: ...Rev 00 03 19 26 Assembly Connection OptiFlex Pro F Spray ...
Page 40: ...Rev 00 03 19 40 Operation OptiFlex Pro F Spray ...
Page 50: ...Rev 00 03 19 50 Disposal OptiFlex Pro F Spray ...
Page 53: ...Rev 00 03 19 OptiFlex Pro F Spray Spare parts list 53 OptiFlex Pro F Spray Spare parts fig 10 ...
Page 58: ......
Page 60: ...Rev 00 ...