Cinterion
®
ENS22-E AT Command Set
2.7 AT+CFUN
ENS22-E_ATC_V01.000
19/02/11
Page 32 of 189
2.7
AT+CFUN Functionality Level
Cinterion
®
ENS22-E's functionality levels. It can also be used to
reset the UE.
Syntax
Parameter Description
0
1
(D)
Minimum functionality.
Shuts down TX and RX RF-circuits whereby
Cinterion
®
ENS22-E logs off
from the net-work. Access to the (U)SIM is also disabled. AT commands
whose execution requires a radio connection or (U)SIM access either return
an error result code (e.g. "+CME ERROR: 524") or reflect the limited
To return to normal mode the command
=1 can be used. After this,
= 0 is necessary for registering to a network.
Full functionality level.
Test Command
AT+CFUN=?
Response(s)
+CFUN:
(list of supported
s), (list of supported
OK
ERROR
+CME ERROR:
Read Command
AT+CFUN?
Response(s)
+CFUN:
OK
ERROR
+CME ERROR:
Write Command
AT+CFUN=
]
Response(s)
OK
ERROR
+CME ERROR:
If
OK
If
OK
^SHUTDOWN
^SYSSTART
PIN Last
Reference(s)
-
-
3GPP TS 27.007
<fun>
(num)