Cinterion
®
ENS22-E AT Command Set
6.8 AT+CEDRXS
ENS22-E_ATC_V01.000
19/02/11
Page 84 of 189
2
Enable the use of eDRX and enable the
unsolicited result code.
3
Disable the use of eDRX and reset the
to
default.
Type of access technology. This parameter is used to specify the relationship between the type of the access
technology and requested eDRX value.
0
Access technology is not using eDRX. This parameter value is only used in the
unsolicited result code
5
E-UTRAN (NB-S1 mode)
Half a byte in a 4 bit format. The values are coded as follows:
“0010“
20,48 seconds
“0011“
40,96 seconds
“0101“
81,92 seconds
“1001“
163,84 seconds
“1010“
327,68 seconds
“1011“
655,36 seconds
“1100“
1310,72 seconds
“1101“
2621,44 seconds
“1110“
5242,88 seconds
“1111“
10485,76 seconds
Half a byte in a 4 bit format. The values are coded in the same way as for
Half a byte in a 4 bit format. The requested values are applied immediately and are stored non-volatile. In case
the module is attached to the network the change of the values will trigger tracking area update. The stored con-
figuration is used during the network attach after restart in case the auto-attach is enabled.
The values are coded as follows:
“0000“
2,56 seconds
“0001“
5,12 seconds
“0010“
7,68 seconds
“0011“
10,24 seconds
“0100“
12,8 seconds
“0101“
15,36 seconds
“0110“
17,92 seconds
“0111“
20,48 seconds
“1000“
23,04 seconds
“1001“
25,6 seconds
“1010“
28,16 seconds
“1011“
30,72 seconds
“1100“
33,28 seconds
<AcT-type>
(num)(NV)
<Requested_eDRX_value>
(str)(NV)
<NW_provided_eDRX_value>
(str)
<Paging_time_window>
(str)