User manual  

 

USB cable; 

 

CD with software 

 

Adaptor(optional, not included) for SiS-PM only 

 

 

6. Installation of SiS-PM(S) 

 

 

It is strongly recommended to avoid damp or wet places for installation.  

 

SiS-PM(S) should be connected to the European AC wall socket of the standard 
DIN 49  440; 

 

SiS-PM(S) can be connected to the computer first and then to the power socket or 

vice-versa. 

 

It is possible to connect the SiS-PM(S) to the power source via other multi-plugs, 

surge protectors, voltage regulators or UPS. 

 

7. Connection of other devices to the SiS-PM 

 

 

Two (the first and the last) sockets of the SiS-PM(S) are marked with the symbol 

 . These two sockets are switched on and off by means of the main power 

switch of the SiS-PM(S) and cannot be managed by the computer. It is suggested 

to use these two sockets to power up the managing computer and the hardware 
schedule adapter;(Optional for SiS-PM only) 

 

The sockets: Socket 1, Socket 2, Socket 3 and Socket 4 can be managed or 
preprogrammed by computer via the USB interface. 

 

SiS-PM(S) can be used with other multi-plugs and/or surge protectors; 

 

You are NOT to connect SiS-PM(S) to powerful machines with inductive type of 
load, for example: welding machines, washing machines, electric drills etc... 

 

SiS-PM-841 can be connected with CAS-441-PM, CAS-841-PM using CAT-5 cable 
marked “Straight-Through Cable Pinout (T568B or T568

А

)” with sockets of PM 

interface 

 

To work with CAS-441-PM it needs to set device’s ID = 1. This can be done using 
the utility software “SiS-PM-841 Configuration Tool” after the device has been 

connected to PC through the USB-cable. To work with CAS-841-PM it needs to set a 
unique ID for each connected device, which will be categorically associated with the 

socket number in CAS-841-PM device. 

 

You can connect up to 10pcs of CAS-841-PM at the same time. Connect the first 
device to RJ-45 socket using the cable described above. Both RJ-45 sockets are 

equal. In this way all devices should be connected in a chain, one SiS-PM-841 to 
another. 

 

 
 

 
 

 

Summary of Contents for Silver Shield Power Manager

Page 1: ...a ag ge er r S Si il lv ve er r S Sh hi ie el ld d P Po ow we er r M Ma an na ag ge er r 8 84 41 1 S Si il lv ve er r S Sh hi ie el ld d P Po ow we er r M Ma an na ag ge er r S S W Wi it th h b bu ui...

Page 2: ...3 Side panel with connectors of the SiS PM 841 4 Hardware requirements 5 Package contents 6 Installation of SiS PM S 7 Connection of other devices to the SiS PM S 8 Switching SiS PM S on and off conn...

Page 3: ...hardware based event time schedule The hardware schedule will work even with the managing computer switched off provided that the is connected to the optional power adapter The unit will keep performi...

Page 4: ...cker switch Indicator Socket 3 Silence button to suppress beeps Indicator POWER USB connector Non manageable socket Indicator Socket 4 Hardware schedule power supply connector 9VDC 0 5A For SIS PM onl...

Page 5: ...allow hardware schedule of SiS PM events to continue working with the managing computer switched off an extra power adapter 9VDC 0 5 is required optional SiS PMS contains the build in power adapter 5...

Page 6: ...for SiS PM only The sockets Socket 1 Socket 2 Socket 3 and Socket 4 can be managed or preprogrammed by computer via the USB interface SiS PM S can be used with other multi plugs and or surge protector...

Page 7: ...et has power to it SiS PM 841 sockets can be controlled by PC and by other external device which can support PM interface in particular CAS 441 PM CAS 841 PM Supervisory external device can read statu...

Page 8: ...t the program which will be launched when the power supply to the socket does not match the required event i e the socket must be on but there is no power supplied to it yet Check the When alarm goes...

Page 9: ...om the present time the loop period should also not exceed the difference between the time of the first entry and the present time plus 45 days 6 Loop period should not exceed 180 days 7 It is also po...

Page 10: ...to for files using the Browse button or typing it manually in the Title and Path name fields Specify the File name mask using wildcard characters After you have specified the folder and file name chec...

Page 11: ...following command line interface syntax is supported pm exe on off device name socket name Examples C Program Files Gembird Power Manager pm exe on sis pm socket1 E Utils PM3 pm exe off my sis pm tab...

Page 12: ...h the sign Indicator Socket x is on means there is power in this particular socket Main rocker switch is light up means SiS PM S is connected to the power supply and the SiS PM S is active 12 Technica...

Page 13: ...www gmb nl forum Disclaimer No effort have been spared to ensure that the information in this manual is correct and complete to the best of our knowledge However no liability is accepted for any erro...

Reviews: