SIS-PM / SiS-PM-841 / SIS-PMS  User Manual 

 

10 Power Manager Help 

 
The 

Settings dialog box

 allows you to change settings for the device sockets. You may 

choose the device and the socket from the "Device" and "Socket" drop down list-boxes.  

 

It is possible to name and assign a certain icon to the device and socket (for 
example “Printer” or “Scanner”) using the "Rename" button.  

 

Check the "Disable device beeper" checkbox to disable the built-in SiS-PM beeper.  

 

Check the "Show socket switch icon" checkbox if you want to put the icon of the 
socket into the system tray. Such an icon is a fast way to switch the device 

connected to the socket on/off or check its status. 

 

You can also assign a hot key to switch the socket on/off. Check the "Switch ON" 
and "Switch OFF" checkboxes and specify the hot keys.  

 

To switch the socket on/off on Windows startup, check the "On Windows startup" 
checkbox and choose the required action.  

 

To switch the socket on/off on Windows shutdown, check the "On Windows 

shutdown" checkbox and choose the required action.  

 

Check the "When alarm goes on start application" checkbox and click the "Browse" 
button to select the program which will be launched when the power supply to the 

socket does not match the required event (i.e. the socket must be on, but there is no 
power supplied to it yet).  

 

Check the "When alarm goes off start application" checkbox and click the "Browse" 
button to select the program, which will be launched after the alarm state (see 
above) is resolved.  

 

To manage SiS-PM(S) from the LAN and/or via Internet, press the button "Device 
sharing...". A dialog box "Device sharing" will appear. Set the checkbox "Share this 

device via network" if you want to enable the network access to the device. To 
prevent unauthorized access to the SiS-PM(S) enter the access password in the field 

"Password". Note: to let SiS-PM(S) work via the network the port 6100 should be 
open. Contact your LAN administrator for further details. 

 
Using the 

Timer schedule

 dialog box you can create the hardware timer schedule:  

 

To add a new record, click the "Add" button. The dialog "Add entry" will appear. In 
the dialog box, specify the required time interval and the action.  

 

To edit the record, select it and click the "Edit"  button  or  just  double  click  on  the 

entry.  

 

To remove the record, select it and click the "Remove" button. You can select 
multiple entries using Ctrl and shift keys. You can also remove all entries from the 

schedule by clicking the "Clear" button.  

Summary of Contents for Silver Shield Power Manager

Page 1: ...a ag ge er r S Si il lv ve er r S Sh hi ie el ld d P Po ow we er r M Ma an na ag ge er r 8 84 41 1 S Si il lv ve er r S Sh hi ie el ld d P Po ow we er r M Ma an na ag ge er r S S W Wi it th h b bu ui...

Page 2: ...3 Side panel with connectors of the SiS PM 841 4 Hardware requirements 5 Package contents 6 Installation of SiS PM S 7 Connection of other devices to the SiS PM S 8 Switching SiS PM S on and off conn...

Page 3: ...hardware based event time schedule The hardware schedule will work even with the managing computer switched off provided that the is connected to the optional power adapter The unit will keep performi...

Page 4: ...cker switch Indicator Socket 3 Silence button to suppress beeps Indicator POWER USB connector Non manageable socket Indicator Socket 4 Hardware schedule power supply connector 9VDC 0 5A For SIS PM onl...

Page 5: ...allow hardware schedule of SiS PM events to continue working with the managing computer switched off an extra power adapter 9VDC 0 5 is required optional SiS PMS contains the build in power adapter 5...

Page 6: ...for SiS PM only The sockets Socket 1 Socket 2 Socket 3 and Socket 4 can be managed or preprogrammed by computer via the USB interface SiS PM S can be used with other multi plugs and or surge protector...

Page 7: ...et has power to it SiS PM 841 sockets can be controlled by PC and by other external device which can support PM interface in particular CAS 441 PM CAS 841 PM Supervisory external device can read statu...

Page 8: ...t the program which will be launched when the power supply to the socket does not match the required event i e the socket must be on but there is no power supplied to it yet Check the When alarm goes...

Page 9: ...om the present time the loop period should also not exceed the difference between the time of the first entry and the present time plus 45 days 6 Loop period should not exceed 180 days 7 It is also po...

Page 10: ...to for files using the Browse button or typing it manually in the Title and Path name fields Specify the File name mask using wildcard characters After you have specified the folder and file name chec...

Page 11: ...following command line interface syntax is supported pm exe on off device name socket name Examples C Program Files Gembird Power Manager pm exe on sis pm socket1 E Utils PM3 pm exe off my sis pm tab...

Page 12: ...h the sign Indicator Socket x is on means there is power in this particular socket Main rocker switch is light up means SiS PM S is connected to the power supply and the SiS PM S is active 12 Technica...

Page 13: ...www gmb nl forum Disclaimer No effort have been spared to ensure that the information in this manual is correct and complete to the best of our knowledge However no liability is accepted for any erro...

Reviews: