Gemini Profiler Specification
Gemini Profiling System
0695-SOM-00001, Issue: 03
17
© Tritech International Ltd.
4.7. Cable Specification
4.7.1. Ethernet Cable
For an Ethernet connection, the supplied cable is described below and should be
terminated with an appropriate connector for the intended application.
Note
Ethernet connection requires a shielded cable (of CAT5e standard) for the
entire cable run (max 80m), lengths of untwisted cable around connectors
must be kept to an absolute minimum. Untwisted lengths will cause poor
or intermittent operation.
This should be connected to the Burton 5506-1508 (
Main
port) on the sonar head.
Ethernet Cable Specification
Burton 55A1-1508
Cable Colour
& Specification
Function
1
Red UTP#2 (24AWG)
Ethernet RX +
2
White UTP#2 (24AWG)
Ethernet RX -
3
Blue UTP#1 (24AWG)
Ethernet TX +
4
Red (20AWG)
DC +
6
White UTP#1 (24AWG)
Ethernet TX -
7
Black (20AWG)
DC Ground (0V)
Minimum dynamic bend radius 130mm (static 36mm)
4.7.2. VDSL Cable
A VDSL connection requires only one twisted pair from the sonar to the surface
housed within a 4 core shielded cable.
Note
The signal path should have a characteristic impedance of 110Ω (±10Ω)
for the entire cable run for optimal performance.
This should be connected to the Burton 5506-1508 (
Main
port) on the sonar head.