Gemini Software Operation
Gemini Profiling System
0695-SOM-00001, Issue: 03
55
© Tritech International Ltd.
Hub Setup Tab
The
Hub Setup
tab allows configuration of the serial ports on the rear of the Gemini
Hub to allow RS232 data to pass through to the Gemini software from external
sensors.
To enable communication with the Hub click on the
Enable Comms
button. To
make sure the correct Hub is being used, an ID can be entered by clicking in the
Hub
ID
text field.
Port
The port letter, corresponding to the label on the back of the
Gemini Hub.
Mode
Can change between an ASCII decode, binary decode or can
echo the data on one of the other ports (ASCII is normal, binary
only used by Simrad EM3000). Echoing the data provides an
alternative option to using a serial splitter cable where a single
data feed is required to be input both to the Gemini system and
to other systems.
Sync
The sync character used to frame the ASCII string.
Baud
The baud rate of the sensor connected to the port.
Decode
The decode definition to apply for the expected receive data on
the port.
Max
Set the time in seconds to generate an alarm if no data is received.