Gemini Software Operation
Gemini 720is Imaging Sonar
Document: 0703-SOM-00002, Issue: 1
47
© Tritech International Ltd.
Note
The
Settings
field of the
Sensors
tab is only active if logging is taking place.
Within the
Settings
field the actions of the operator are recorded so that during
play back of the log file it is possible to see which settings have been changed.
Note
If serial sensor data is shown here, a subset of the data will also be shown at
the bottom of the
User
screen.
5.3.2. Gemini Hub
Hubs Tab
The
Hubs
tab shows the status information from any connected Gemini Hubs.
Hub Setup Tab
The
Hub Setup
tab allows configuration of the serial ports on the rear of the Gemini Hub to
allow RS232 data to pass through to the Gemini software from external sensors.
Port
The port letter, corresponding to the label on the back of the Gemini
Hub.
Mode
Can change between an ASCII decode, binary decode or can echo
the data on one of the other ports (ASCII is the default input, only the
Simrad EM3000 uses a binary input). Echo is used as an alternative to
a serial splitter cable in systems where the sensor data is also used by
another application or device.
Sync
The sync character used to frame the ASCII string.