5.7. Settings Files
The Gemini software stores all the settings in the file
C:\GeminiData\Settings
\Gemini.xml
. A backup of this file can be kept as a record of all the Gemini settings. When
contacting
Tritech International Ltd
Technical Support it may be necessary to supply a copy
of this file.
The Gemini software keeps a historical log of settings files in the folder
C:\GeminiData
\Settings
, with folder and file names automatically generated from the date and time. This
can be useful for restoration of previously known good settings. To use a previous settings
file:
1. Shut down the Gemini software.
2. Delete (or rename) the
C:\GeminiData\Settings\Gemini.xml
file.
3. Copy the historical settings (*.xml) file into the location
C:\GeminiData\Settings
and
rename it to
Gemini.xml
4. Start the Gemini software.
A factory settings file is stored in the install folder (normally
C:\Program Files\Tritech
\Gemini\Factory.xml
). To revert completely to the factory settings file:
1. Shut down the Gemini software.
2. Delete (or rename) the
C:\GeminiData\Settings\Gemini.xml
file.
3. Copy the
Factory.xml
file into the location
C:\GeminiData\Settings
and rename
it to
Gemini.xml
4. Start the Gemini software.
5.8. Keyboard Shortcuts
A number of keyboard shortcuts are available for commonly used activities.
F7
Toggle Logging of data
Ctrl F
Capture the screen to file
A
Increase gain
Z
Decrease gain
D
Increase range
C
Decrease range