background image

GEMO

GEMO

GEMO

GEMO

DS204

PRESET UP/DOWN COUNTER

         Attention       

        High Voltage,

 Double / Reinforced            NOT

            CE Mark

    Risk of Danger,   

             Risk of         

          Insulation

         Litter

         Warning         

       Electric Shock

TECHNICAL SPECIFICATION

Dimensions

: 48x48mm

Panel Cut-out

: 45,5x45,5mm

Display

: 2x4 Digits 7 Segment

Count Input

: 2 x (Max:7500 Hz, 5-30V)

Reset Input

: 10ms (min), Positive input (PNP only) (5..30V)

Output 

: Out; Relay (O-NO-NC), 250VAC, 2A, Resistive load

  open collector (NPN), 30V, 100mA max.

Sensor types

: PNP/NPN proximity switch - NPN/PNP/Totem-pole output encoder

Input frequency

: 20, 500, 2500, 7500Hz selectable

NPN Selection

: Connect “npn select” to “+12V” to select NPN sensor for CP1 and CP2.

Reset input is always PNP. For totem pole or PNP type sensor “npn select”

  left unconnected.

Sensor Supply Out

: 12VDC, 50mA max. (unregulated)

Supply Voltage

: 100..240VAC, 50-60Hz or 24Vac/dc (optional)

Power Consumption : < 6VA

Humidity

: 80% up to 30

o

C, then linearly decreases to 50% at 50

o

C (non-condensing)

Altitude

: < 2000 m

EMC

: EN 61000-6-1, EN 61000-6-3 (Only light industrial environment)

Safety

: EN 61010-1; Pollution degree 1, measurement category 

I

, (Only light industrial

  environment, double/reinforced isolated, non-conductive pollution environment)

Protection Class

: IP20; according to EN 60529

Storage Temperature : -10

o

C .. 60

o

C (no icing)

Operation Temp.

: 0 .. 50 

o

C

Weight

: < 0.5 kg

Key

: Micro switch

Torque for screwing : Max. 0.5 N.m

no: 

normally open

nc: 

normally closed

Gürbüzo

ğ

lu Elektronik San. ve Tic. Ltd. 

Ş

ti.

http://www.gemo.com.tr

Çamlıtepe Cad. No:297 / 3-4 Siteler, Ankara, Türkiye

e-posta: info@gemo.com.tr

Tel: +90-312-3503900, Fax: +90-312-3511117

1

9

9

8

8

+12V 50mA

+12V 50mA

npn select

npn select

+

+

-

Out

Out

PNP/NPN Proximity

Switch (***)

PNP/NPN Proximity

Switch (***)

Reset

Switch

Reset
Switch

Sayma 2
(ör:A

ş

a

ğ

ı)

Sayma 1
(ör:Yukarı)

10

10

C.P.1 Input

C.P.1 Input

11

11

C.P.2 Input

C.P.2 Input

12

12

Reset In

Reset In

13

13

SS Out

SS Out

14

14

Gnd

Gnd

9

8

+12V 50mA

npn select

+

+

-

Out

Out

Totem-Pole

Encoder

Reset

Switch

30Vdc

(Max)

(*)

(**)

10 C.P.1 Input

11 C.P.2 Input

12 Reset In

13 SS Out

14 Gnd

(*) Connect
SS Out return
pin directly to
GNG

(**) Use free-
wheeling  diode to
protect  SS Out

(***) To select NPN option;
connect “npn select” to
“+12V”. 

Reviews: