MODES OF OPERATION

Notes:
1. For Mode1; t.On and t.OFF are accepted as min. 000.1 sec, 00.01 min. and 00.01 hr.
2. Timer counts up for Mode 6 & 7, and down for other modes.
3. For all modes; counting is inhibited (freeze) when GATE is ON.

CLAEANING

Do not use any solvents (alcohol, thinners, benzine, acid, etc.) or corrosive substances to clean the device. 
Use only a dry and clean non-abrasive cloth. Before cleaning, disconnect the power supply and mains 
connections.

Gürbüzo

ğ

lu Elektronik San. ve Tic. Ltd. 

Ş

ti.

http://www.gemo.com.tr

Çamlıtepe Cad. No:297 / 3-4 Siteler, Ankara, Türkiye

e-posta: info@gemo.com.tr

Tel: +90-312-3503900, Fax: +90-312-3511117

4

tA

tA

tB

tB

t.On

t.On

t.On

t.On

t.OFF

t.OFF

t.OFF

t.OFF

t.SEt

t.SEt

t.SEt

t.SEt

t.SEt

t.SEt

t.SEt

t.SEt

t.SEt

t.SEt

Mode : 4; Follow & 

ON Delay

Mode :  ; 

2

One Shot after ON and OFF

Mode :  ;

1  

Flashing with START/RESET

Mode :  ; 

6 Chronometer - Count with START

Mode :  ; 

7 Chronometer-Count with START, Reset with RESET

Mode :  ; 

5

Delayed One Shot after OFF

Mode :  ; 

0

Pulsed Delay, OFF with RESET

Mode : 3; 

OFF Delay

t.SEt

Start

Start

Out1

Out2

Out1

Out2

Out1 is ON when Start input is ON.
Out2 becomes ON "t.SEt" after START
input is ON. Out1 & 2 are OFF when
START input is OFF. Out1 & 2 are OFF
when RESET input is ON .

Out1 & 2 become ON when
START input is triggered
(OFF > ON) or (ON > OFF)
and become OFF after "t.SEt".
START input can re-trigger
when Out1 & 2 are ON.
Out1 & 2 are OFF when
RESET input is ON.

Out1 & Out2 are periodically first
ON for "t.On" and then OFF for 
"t.OFF” after START input is
triggered (OFF > ON). Out1 & Out2
are OFF when RESET input is ON.

1

Out2 is ON

when timer elapses T.SEt. 

& 2 are OFF 

 

Out1 & 2 are OFF when

RESET input is ON.

Out  is ON and timer counts up
when START is ON. Timer freezes
when START is OFF. 

Timer

resets and Out1 

when

START is OFF after Timer elapses
T.SEt. 

1

Out2 is ON

when timer elapses T.SEt. 

& 2 are OFF when

RESET input is ON.

Out  is ON and timer counts up
when START is ON. Timer freezes
when START is OFF. 

Timer

resets and Out1 

Out1 & 2 are first ON after "tA" and then
OFF after "tB" when START is triggered
(ON > OFF). START input does not
re-trigger before "tB" elapses. Out1 & 2
are OFF when RESET input is ON.

t.SEt

t.SEt

Start

Start

Start

Start

t.SEt

t.SEt

Start

Reset

Reset

Gösterge

Gösterge

Out1

Out2

Out1

Out2

Out1

Out2

Out1

Out1

Out2

Out2

Reset

Out1 & Out2 become ON "t.SEt" after
START input is triggered (OFF > ON).
START input can not re-trigger timer
until it is reset with RESET input. Out1
& Out2 are OFF when RESET input is ON.

Start

Out1

Out2

Out1 & 2  become ON when START
input is ON. Out1 & 2 become OFF
"t.SEt" after START input is triggered
(ON > OFF). Out1 & 2 are OFF when
RESET input is ON . 