GemOro Powerful Ultrasonics
4
Super Concentrate Cleaning Solution or Sparkle Pak PRO pre-measured
cleaning solution packets. WARNING: Do not use flammable (alcohol
based solutions, etc.), basic/alkaline (Drano, etc.) or ammonia based
solutions (Mr. Clean, etc.) in your ultrasonic. Under any circumstances,
NEVER TURN THE UNIT ON WHILE THE TANK IS EMPTY. Place the
water/cleaning solution mixture in the tank with the solution filling the
tank up to approximately one inch from the top edge of the tank.
At this time, to expedite the natural degassing process, you may wish
to run the Digital Degas feature. Water that has not been degassed
will cause the cavitation (action) of the ultrasonic to appear very
slow or flat. More details on degassing can be found on page 5.
HOW TO OPERATE MODEL 2.6QTH-D
1. Press the POWER button to turn the unit on.
2. Press the HEATER button to turn on the units heater if desired. The
blue LED light on the right of the display will indicate the heater has
been activated. The unit will quickly heat up to the optimal preset
cleaning temperature that has a maximum temperature of 65C or
149F. Once the heater has reached its maximum temperature the red
LED light on the right of the display will light up.
3. Press the TIMER button repeatedly to scroll through the timed
cleaning cycle options (90, 180, 280, 380 or 480 seconds).
4. Once you’ve selected the desired cleaning time, press the
ULTRASONIC button to activate the ultrasonic.
5. If you wish to expedite the natural degassing process, press the timer
button to the desired degassing time of (90, 180, 280, 380 or 480
seconds). Then press the DEGAS button and the unit will cycle on
and off as it performs its digital degassing process until the degassing
time has ended. Once you’ve performed the degassing process,
follow steps 3 and 4 to use the ultrasonic function.
CLEANING GUIDE
Submerge the jewelry to be cleaned in the tank no less than a 1/2 inch
below the solutions surface to obtain optimal cleaning. Be certain not
to place jewelry or anything being cleaned on the bottom of the tank,
because it may damage the transducers and void the warranty. Be
careful not to clean stones that may have many inclusions (example:
emeralds), because the ultrasonic waves and heat may crack the stone.
Be certain not to clean soft, water porous stones (such as pearls,
opals, turquoise, etc.) as they too may be damaged. Be certain not to
clean any oil treated stones in any cleaning solution which may contain
a degreasing agent, as the solution may revert the stone back to its